Back to blog
Article

House Prefabricated Panel Models

Admin September 18, 2026

House prefabricated panel models are primarily classified based on dimensions, load-bearing capacity, and intended use, with common models covering a variety of specifications. Selection should be tailored to specific needs.

1. Classification by Dimensions

The dimensions of prefabricated panels directly influence their suitability for different scenarios and are typically defined by three parameters: length, width, and thickness.
Length: Standard panels are mainly available in lengths of 3000mm, 3300mm, 3600mm, 3900mm, and 4200mm, with 4200mm being the most commonly used. Special panels include 3800mm and 4000mm, suitable for specific span requirements.
Width: The main specifications are 400mm, 500mm, and 600mm. Panels with a width of 400mm usually feature a four-hole structure, those with 500mm have a five-hole structure, and 600mm wide panels are often used in large-span scenarios.
Thickness: Common thicknesses are 120mm and 150mm, with some special models reaching 180mm or 200mm. Increasing thickness enhances load-bearing capacity.
Examples of Specific Models:

  • Solid Panels: Such as 2400×1200×100mm, suitable for small-span areas (e.g., bathroom and kitchen floors) due to their stable load-bearing capacity but relatively heavy weight.
  • Hollow Panels: Such as 3000×600×150mm, with a hollow center design to reduce weight, making them a common choice for ordinary residential floors.
  • Special-shaped Panels: Such as 4500×900×180mm, customized for special housing layouts (e.g., balcony cantilever panels, stair treads), requiring prior planning of dimensions.

2. Classification by Load-Bearing Capacity

The load-bearing capacity of prefabricated panels is determined by material strength and structural design, necessitating the selection of an appropriate grade based on the building type.
Lightweight Prefabricated Panels (≤150kg/m²): Primarily used for non-load-bearing walls or partitions (e.g., office partition walls), offering low self-weight and cost.
Medium-duty Prefabricated Panels (150 - 250kg/m²): The mainstream choice for floors, suitable for residential buildings or shops up to six stories high, balancing economy and load-bearing requirements.
Heavy-duty Prefabricated Panels (≥250kg/m²): Used in load-bearing structures of high-rise buildings (e.g., office building core tube floors), requiring prestressing technology to enhance crack resistance.
Classification by Live Load Capacity:

  • Grade I Panels (1kN/m²): Suitable for areas with low load requirements (e.g., storage rooms).
  • Grade II Panels (2kN/m²): Commonly used for ordinary residential floors.
  • Grade III Panels (3kN/m²) and Grade IV Panels (4kN/m²): Used in commercial or industrial buildings, with some regions requiring a minimum standard of Grade IV panels.

3. Selection of Appropriate Models Based on Intended Use

Different construction scenarios impose varying performance requirements on prefabricated panels, necessitating targeted model selection.
Residential Floors: Priority is given to 2000×1200×160mm medium-duty hollow panels, which balance load-bearing capacity and economy, suitable for most multi-story residential buildings.
Industrial Plants: Recommended are 3000×1500×200mm heavy-duty solid panels, offering strong impact resistance and the ability to withstand equipment vibrations or cargo stacking.
Municipal Engineering: Bridge prefabricated panels often adopt 5000×800×250mm prestressed panels, utilizing prestressing technology to increase span capacity and reduce the number of supporting structures.

Summary: The selection of house prefabricated panel models requires consideration of dimensions, load-bearing capacity, and intended use. For ordinary residential buildings, priority can be given to medium-duty hollow panels, while industrial or high-rise buildings necessitate the use of heavy-duty or prestressed models. Special scenarios may require customized special-shaped panels. During the design phase, it is essential to combine building codes with actual needs to ensure model suitability.