Wall Thickness of Prefabricated House Flue
The wall thickness of prefabricated house flues varies depending on the region and type, as detailed below:

For prefabricated cement flues in residential kitchens, there is a relatively common standard wall thickness setting, typically 5 cm. This standard is applicable to most ordinary residential kitchen scenarios and can meet basic smoke exhaust requirements as well as structural stability requirements.
In the Taizhou region, there are clear regulations for prefabricated concrete flues. Their wall thickness must be ≥ 100 mm, and there are also strict requirements for the flatness of the inner wall, with an error tolerance of ≤ 3 mm. Additionally, waterproofing treatment must be carried out at the joints. When the building height exceeds 100 m, the wall thickness needs to be increased by 10% - 15% on the basis of the standard value. This is because high-rise buildings are subject to greater external forces such as wind and earthquakes, which place higher demands on the structural strength of the flues. Increasing the wall thickness can enhance the flue's resistance to deformation and damage. Moreover, for multi-household shared flues, the wall thickness of the public flue should be ≥ 150 mm. Multi-household shared flues are used frequently and have a large smoke exhaust volume. A thicker wall thickness can ensure that the flue will not be damaged by smoke exhaust pressure during long-term use and can also reduce mutual interference in smoke exhaust between different households.
The Ningbo region also has its specific standards. Prefabricated components with a thickness of 15 - 20 mm are recommended for cement flues in residential kitchens. This thickness can meet the basic smoke exhaust requirements of residential kitchens while also controlling costs and construction difficulty to a certain extent. For flues in public buildings such as shopping malls and office buildings, the wall thickness of cement flues needs to reach 20 - 30 mm. Public buildings have a high density of people and a large smoke exhaust volume, requiring a thicker wall thickness to ensure the stable operation of the smoke exhaust system. If the length of the flue exceeds 5 meters or it is installed in a high-rise building (> 30 meters), it is recommended to increase the wall thickness by 5 - 10 mm. An increase in the length of the flue will increase the smoke exhaust resistance, and high-rise buildings face greater wind and air pressure changes. Increasing the wall thickness can improve the flue's pressure and deformation resistance, ensuring smooth smoke exhaust.