Guidong Mobile Toilet Inspection
The inspection of mobile toilets in Guidong typically covers multiple aspects, including structural safety, internal equipment, water supply and drainage systems, electrical systems, environmental protection systems, sanitary conditions, and facility functionality.

Structural Safety Inspection: It is necessary to check whether the overall structure of the public toilet is stable, and whether there are issues such as tilting, cracks, or deformation. Evaluate the stability of the box frame, wind and earthquake resistance, and the anti-slip performance of the floor. At the same time, check whether the door and window locks are reliable to ensure safe use. Inspection methods include visual inspection and mechanical testing, such as using pressure testing equipment to check the load-bearing capacity of the public toilet floor.
Internal Equipment Inspection: Focus on checking the integrity and working condition of equipment such as toilets, urinals, and sinks. Observe whether there are damages or cracks on the exterior, and check whether the drainage functions of each piece of equipment are unobstructed through actual operation to ensure normal equipment operation.
Water Supply and Drainage System Inspection: Check the water supply pressure of the water supply system and the drainage capacity of the drainage system. Use a water pressure gauge to test whether the pressure in the water supply pipes is within the normal range, and test the smoothness of the drainage pipes through actual water discharge to ensure there are no leaks or blockages.
Electrical System Inspection: Check the safety and functionality of the electrical system, including lighting, ventilation, and heating devices. Use a voltmeter and ammeter to test the working voltage and current of electrical equipment to ensure they are within safe limits. At the same time, conduct actual operation checks on the working status of each piece of electrical equipment, such as whether the lighting is normal and whether the ventilation is effective.
Environmental Protection System Inspection: Check the working status of water-saving devices and deodorization devices. Test the water-saving effect through actual water consumption, and use an odor detector to check the working effect of the deodorization devices to ensure there is no odor and meet environmental protection requirements.
Sanitary Condition Inspection: Check the overall sanitary condition of the mobile public toilet, including whether the floor, walls, and equipment surfaces are clean and hygienic. Evaluate the internal sanitary condition of the public toilet through visual inspection and bacterial testing to ensure it meets sanitary standards.
Facility Functionality Inspection: Test the stability of the water pressure in the flushing system, water-saving efficiency, and the smoothness of the sewage pipes. Check whether lighting, ventilation, and barrier-free facilities (such as handrails and ramps) meet national standards. For some new types of mobile public toilets, it is also necessary to test the operating status of solar power supply systems and smart sensing devices.