Back to blog
Article
Zhoushan Mobile Toilet Installation
Admin September 23, 2026
The installation of mobile toilets in Zhoushan requires comprehensive consideration of technical configuration, service selection, and operational specifications to ensure stable equipment operation and a good user experience.

1. Technical Configuration: Rational Construction of Modular Systems
Mobile toilets are integrated systems comprising three core modules:
- Toilet Unit Module: Choose between squat or sit-type toilets based on the usage scenario, ensuring the interior space meets ergonomic standards (e.g., a net width of ≥0.8 meters) to avoid discomfort due to cramped conditions.
- Waste Treatment and Storage Module:
- For circulating water-flush types, equip with a biodegradation device that uses microorganisms to decompose waste and recycle water, suitable for long-term use scenarios.
- For bagging types, regularly replace the fecal storage bags, reserve operational space, and ensure airtightness to prevent odor leakage.
- For direct-discharge types, connect to the municipal drainage system, confirming the site's drainage conditions in advance.
- Auxiliary Support Module:
- Water Supply Module: If using a water-flush type, connect to the municipal water supply or equip with a water tank (recommended capacity of ≥500L/day).
- Power Supply Module: Lighting, ventilation, and other equipment require a stable power source, which can be connected to the municipal power grid or use a mobile power supply (power ≥1kW).
- Structural Stability Module: Choose a fixation method based on ground conditions (e.g., mud or hard ground), such as expansion bolt fixation or weight block reinforcement, ensuring a wind resistance rating of ≥8.
2. Service Selection: Key Elements of Professional Rental Companies
- Quantity Configuration: Calculate based on event scale and site conditions, recommending one standard toilet per 50 people, with a 20% redundancy during peak times.
- Installation Plan: Regular service providers offer free on-site surveys and design plans based on terrain:
- For lawns, lay anti-settlement foundations.
- For muddy ground, harden the surface or use deep pile fixation.
- For hard ground, confirm load-bearing capacity (recommended ≥300kg/㎡).
- Supporting Services:
- Water and electricity access: Some service providers offer mobile power and water tank rentals.
- Cleaning and maintenance: At least one daily collection and disinfection to prevent waste accumulation.
- Emergency response: 24-hour fault repair services to ensure equipment availability of ≥95%.
3. Operational Specifications: Installation Steps and Precautions
- Basic Installation:
- Use an electric drill (equipped with a 4.2mm drill bit) to drill holes in the ground, with a depth of ≥50mm.
- Insert expansion bolts and fix the base frame, ensuring a horizontal error of ≤2mm.
- When assembling wall panels, insert the panels into the slots and align them, drill holes, insert rivets, and secure them with a rivet gun.
- Module Connection:
- Seal the connection between the waste treatment module and the toilet unit using silicone gaskets to prevent leakage.
- Install check valves in the water supply pipes to prevent backflow of sewage.
- Ground the electrical circuits to prevent electric shock risks.
- Acceptance Criteria:
- Flush pressure of ≥0.15MPa, with smooth drainage.
- Ventilation system air exchange rate of ≥8 times/hour, with no residual odor.
- Structural stability test: Simulate a wind force of 5, with no shaking or displacement of the equipment.
Through the synergy of technical configuration, service selection, and operational specifications, efficient installation and long-term stable operation of mobile toilets in Zhoushan can be achieved.