Back to blog
Article

Best Practices for Toilet Relocation

Admin September 26, 2026

Toilet relocation should be selected based on a combination of drainage type, relocation distance, and apartment layout, prioritizing short-distance relocation or same-floor drainage modification to avoid the risks associated with long-distance relocation.

I. Short-Distance Relocation: Toilet Relocator

Suitable for relocation distances ≤50 cm (some sources suggest ≤80 cm, but ≤30 cm is safer). The following points should be noted:

  • Slope Reservation: Reserve at least 0.5 cm of slope per 10 cm of pipe to ensure smooth drainage. If the relocation exceeds 10 cm, it is recommended to use a direct-flush toilet to reduce the risk of blockage.
  • Limitations: The longer the relocation distance, the higher the probability of blockage. Relocation beyond 1 meter is not recommended.

II. Same-Floor Drainage Modification: Highest Degree of Freedom

If the bathroom has same-floor drainage (drainage pipes are within the same floor), the degree of freedom for modification is significantly increased:

  • Direct Pipe Modification: Achieve relocation by adjusting the position of the drainage pipes on the same floor. Overall lowered floor design allows for flexible arrangement.
  • Wall-Mounted Toilet: Embed the water tank and drainage pipes into the wall to reduce floor space usage, but ensure close modification of the drainage pipes.
  • Advantages: No need to damage the floor slab, no need to negotiate with neighbors downstairs, wide modification range, and low risk.

III. Inter-Floor Drainage: Requires Negotiation but Has a Low Success Rate

If the bathroom has inter-floor drainage (drainage pipes are within the ceiling of the floor below), it is necessary to negotiate with neighbors to drill holes in the floor slab and re-lay pipes. However, the actual success rate is extremely low (only about 1%), and it may lead to neighbor disputes. It should only be considered as a last resort.

IV. Other Auxiliary Methods

  • Floor Elevation: Hide long-distance pipes by raising the floor, but this will sacrifice ceiling height (usually raised by 15-30 cm), suitable for apartments with sufficient ceiling height.
  • Floor Drain to Wall Drain Conversion: Lay drainage pipes along the wall to reduce the length of floor pipes, but plan in advance for wall thickness and inspection ports.

Summary of Core Principles

  1. Distance Priority: The shorter the relocation distance, the better (recommended ≤30 cm, maximum ≤1 meter). Long-distance relocation requires a comprehensive assessment of blockage risks and costs.
  2. Slope Guarantee: After relocation, ensure the slope of the pipes, and the outlet must be raised to form gravity drainage.
  3. Drainage Type Determines the Plan: Same-floor drainage modification offers the highest degree of freedom, while inter-floor drainage requires careful negotiation.

If conditions permit, prioritize same-floor drainage modification or short-distance toilet relocators. For long-distance relocation, combine floor elevation or wall drain design and take anti-blocking measures.