Information about the outdoor mobile toilet in Shangyou County is as follows:

I. Bidding Project Jiuding Ganrao Intermediary Service Consulting Co., Ltd. has been entrusted by the Shangyou County Urban Management Bureau to conduct an electronic public bidding for the prefabricated mobile toilet project, with the project number JDGR2019-SY-G025.
II. Main Technical Specifications and Requirements
- Steel Frame: The model is determined according to the length of the toilet. Galvanized steel is used for anti-corrosion treatment, and the welding process is shielded arc welding. For bottom frames under 10 meters, 120mm national standard galvanized channel steel is used, and for columns, 100mm×100mm national standard galvanized square steel is used; for bottom frames between 10 and 15 meters, 160mm national standard galvanized channel steel is used, and for columns, 80mm×80mm national standard square steel is used; for other columns and crossbeams, 50mm×50mm national standard galvanized square steel is used. Bidders are required to provide scanned copies of the original safety inspection reports for the steel frame's resistance to hurricanes and earthquakes issued by provincial-level or above building inspection institutions.
- Walls: The exterior walls are made of imitation marble tiles, with fingerprint-free rose stainless steel plates or marble corners at the four corners; the base layer is made of double-layer 1mm galvanized plates or PCV plates; the interior wall panels are made of 300mm×600mm imitation marble tiles. Scanned copies of the original tile adhesive inspection reports issued by third-party CMA inspection institutions are required.
- Roof: The base layer is made of 1mm galvanized steel plate, the insulation layer is made of 12mm extruded polystyrene board, the asphalt shingles are of the Owen's brand (1000mm×1500mm×3mm), the eaves are made of fingerprint-free rose stainless steel plates, and lifting points are set at the bottom.
- Internal Configuration: The squatting positions are equipped with water-saving tank flushing + automatic flushing systems, high-quality ceramic squatting pans, stainless steel bag hooks, toilet paper holders, and waste paper baskets; the third toilet includes adult/child toilets, child seats, ceramic washbasins (with sensor faucets and stainless steel handrails), makeup mirrors, baby changing tables, and emergency call buttons; the urinal area is equipped with 3-4 sensor urinals and partitions; the handwashing area is equipped with marble countertop washbasins, sensor faucets, makeup mirrors, toilet paper holders, hand dryers, and air fresheners; the tool room includes a mop sink, hooks, and 304 stainless steel floor drains.
- Fecal Treatment: A three-stage septic tank is used.
III. Key Points for Supporting Facilities in Leasing Activities
- Preliminary Planning: Estimate the demand at 1-2 toilets per 100 people, and increase the number of spare toilets by 20% for activities lasting more than 12 hours.
- Site Selection: Within 30 meters of the main activity area, avoid low-lying and damp areas, ensure the foundation is 30cm above the ground to prevent water accumulation, and reserve wheelchair access of no less than 0.9 meters.
- Quantity Configuration: For concerts, allocate 10 toilets per 500 people; for exhibitions, allocate 1 toilet per 2000 square meters; if there is a children's area, an additional accessible toilet should be provided, and a trial run of 30 minutes should be conducted before use.
- Supporting Facilities: Provide anti-slip mats, lighting systems (essential for nighttime activities), mosquito repellent devices, and red-and-white directional signs outside the toilets (visible from 50 meters away).
- Daily Maintenance: Replenish toilet paper and hand soap every 2 hours, check the sealing after heavy rain, strengthen ventilation during the rainy season, and clean and disinfect within 24 hours after the end of the activity.