Requirements for Prefabricated Partition Walls in Houses
Prefabricated partition walls in houses must meet requirements for structural safety, physical properties, construction techniques, cost-effectiveness, and other specifications, as detailed below:

Structural Safety:
Partition walls must possess sufficient strength and stability, withstanding self-weight, loads, and external forces such as wind and earthquakes through reasonable material selection, cross-sectional design, and reliable connections. It is strictly prohibited to remove or modify load-bearing partition walls arbitrarily. If modifications are necessary, the original design unit or a qualified organization must be commissioned to propose a plan and carry out the construction to ensure the overall seismic resistance and safety of the building.
Physical Properties:
- Thermal Performance: Insulation measures should be taken according to climatic conditions to ensure indoor thermal comfort.
- Sound Insulation: Noise transmission should be controlled through material thickness, density, or composite structures. Partition walls between residential units must achieve a sound insulation level of 50 decibels, while special venues such as conference rooms should reach 55 decibels.
- Fire and Water Resistance: The fire resistance time of ordinary partition walls should be increased to 1.5 hours, and core tube firewalls should reach 3 hours. Pipes passing through walls should be sealed with elastic fire-resistant sealant, with a blocking depth of no less than one-third of the wall thickness. Waterproofing should be carried out in areas such as bathrooms.
- Moisture and Condensation Prevention: Horizontal or vertical moisture barriers should be installed according to the environment to prevent wall damage from moisture.
Construction Techniques:
- Adapt to the characteristics of factory prefabrication and on-site assembly. For example, the thickness of a single cement fiber decorative board is approximately 8-9 centimeters, and the total thickness after construction can be reduced to within 12 centimeters.
- Strict construction accuracy requirements: The allowable deviation for wall verticality has been adjusted from 5 millimeters to 3 millimeters, and the wall surface flatness error must not exceed 2 millimeters.
Cost-Effectiveness:
Under the premise of meeting functional requirements, costs should be reasonably controlled to avoid excessive investment.
Other Specifications:
- Materials must comply with national standards, such as bricks and blocks meeting strength and durability requirements.
- Comply with local urban and rural planning, including height, style, and materials. Historical and cultural villages or protected areas must maintain a consistent appearance; applications for permits must be made in advance in areas with strict planning management.
- Do not obstruct ventilation, lighting, or sunlight for adjacent buildings, avoid excessive height or proximity in construction; ensure the normal operation of drainage systems and do not impede drainage; It is strictly prohibited to encroach on collective land such as roads and public passageways to safeguard passage and usage rights.