The installation of mobile toilets has the following basic requirements for the foundation:

1. Load-bearing capacity
The foundation must have sufficient load-bearing capacity to support the weight of the mobile toilet and prevent sinking or tilting. Lightweight mobile toilets typically require a foundation bearing capacity of no less than 100 kPa, while large modular toilets need higher bearing values determined by specific type, size, and usage load calculations. Insufficient foundation bearing capacity may lead to structural deformation or damage to connecting parts of the toilet, affecting safety in use.

2. Flatness
The foundation surface should be flat, with an error controlled to no more than 20 mm per square meter. An uneven foundation can cause issues such as shaking, loosening of connecting parts, or seal failure after toilet installation, shortening equipment lifespan and increasing maintenance costs. During construction, leveling instruments should be used for detection, and local filling or grinding should be carried out if necessary.

3. Stability
The foundation site should avoid areas with a high incidence of geological disasters, such as landslide- and mudslide-prone areas. If the foundation is soft soil (such as silt or backfill), methods such as sand and gravel replacement, layered compaction, or piling should be used to improve density and prevent toilet tilting or cracking due to foundation settlement after long-term use.

4. Size and space
The foundation size should be slightly larger than the bottom outline of the mobile toilet, with at least 20-30 cm of installation and maintenance space reserved around it. The reserved space facilitates equipment fixation, pipeline connection, and daily maintenance, avoiding operational difficulties or secondary damage to the foundation due to insufficient space.

5. Surface quality
The foundation surface should be solid, crack-free, and free of loose particles or debris. Cracks may expand due to temperature changes or load effects, reducing the overall integrity of the foundation; a loose surface will affect the bonding force between the toilet and the foundation, resulting in poor fixation. After construction, compaction testing should be carried out to ensure surface density.

6. Anti-corrosion treatment (special environments)
In corrosive environments such as seaside areas and chemical plants, the foundation should use anti-corrosion materials (such as epoxy resin coatings) or select corrosion-resistant building materials (such as adding anti-corrosion agents to concrete) to prevent erosion by seawater and chemicals, which can cause steel bar corrosion or concrete deterioration, and extend the service life of the foundation.

The above requirements should be comprehensively evaluated in combination with on-site geological conditions, climatic environment, and toilet type. If necessary, professional engineers should conduct design verification to ensure safe and reliable installation.