The inspection of Datong mobile environmental toilets requires a comprehensive assessment combining the performance of core components, technical stability, and daily maintenance records. Currently, there is no unified local standard, but the following inspection directions can be referred to:

1. Core Component Performance Inspection The core components of mobile environmental toilets (such as smart toilets, vacuum suction toilet fixtures, and ventilation systems) can be inspected with reference to the inspection standards for split-type smart toilets (lids). For example, it is necessary to inspect whether the energy consumption per cycle meets energy-saving requirements, whether the average water consumption for cleaning meets the standards, whether the self-cleaning function of the nozzle can effectively remove stains, and whether the heating temperature of the toilet seat is stable and in line with human comfort. In addition, the air volume and deodorization effect of the ventilation system need to be measured with professional equipment to ensure air circulation without odors; the suction force of the vacuum suction toilet fixtures needs to be verified to ensure they can quickly handle excreta and avoid blockages or leaks.

2. Technical Stability and Safety Verification If microbial degradation technology is used, it is necessary to focus on inspecting the decomposition efficiency of the microbial agent and the stability of the system operation. For example, by simulating usage scenarios, monitor whether the decomposition rate of the microbial strain within 24 hours meets the design standards, and at the same time, check whether the main engine transmission, heating system, and the microbial strain mixing process work in coordination to avoid microbial strain inactivation or treatment interruption due to mechanical failures. In addition, it is necessary to verify the endurance capacity of the solar power supply device to ensure that basic functions can still be maintained during rainy or cloudy weather.

3. Daily Maintenance and Structural Safety Inspection The cleaning and maintenance of mobile toilets need to form a standardized process, including regular excreta suction, internal disinfection frequency (it is recommended to be at least once a day), structural stability inspection (such as whether there are cracks in the walls and floors), and connection tightness testing (such as whether there are leaks at the sewage pipe interfaces). For public toilets put into use in high-traffic areas such as the Datong Ancient City, it is also necessary to refer to the system of "专人值守、一客一洁 (dedicated personnel on duty, cleaning after each use)" and trace the cleaning quality through maintenance records to ensure that the facilities are always in a usable state.

4. Functional Integrity Assessment Taking the mobile public toilets in the Datong Ancient City as a reference, it is necessary to inspect whether the smart lighting system can automatically adjust the brightness according to the ambient light, whether the ventilation and deodorization system can continuously maintain fresh air, and whether the emergency call device is sensitive and reliable. For toilets equipped with barrier-free facilities, it is also necessary to verify whether the ramps, handrails, etc. comply with barrier-free design specifications to ensure the safety of use by special groups of people.