Container House Water Supply and Drainage Design
The water supply and drainage design of container houses should incorporate their modular characteristics, focusing on pipeline layout, waterproof sealing, material selection, and system optimization, while also meeting regulatory requirements and adapting to the special structure of containers.

1. Pipeline Layout and System Design
The pipeline layout for water supply and drainage in container houses should make full use of the internal space, typically adopting concealed installation. Water supply pipelines can be laid concealed along the inner walls or floors of the container, with maintenance openings reserved; drainage pipelines are recommended to use same-floor drainage design to avoid damaging the container structure. For multi-story container combinations, the water supply system should be zoned, such as using variable-frequency pressurization equipment for zoned water supply, and the drainage system should be equipped with ventilation pipes to prevent negative pressure. If the container is used for scenarios like shower rooms, a rainwater collection system can be designed to achieve water resource recycling, but it must be ensured that the water quality meets usage standards.
2. Waterproofing and Sealing Treatment
The joints between containers, around doors and windows, and where pipelines pass through walls are key areas for waterproofing. All gaps should be sealed with weather-resistant sealant and regularly inspected and replaced (it is recommended to replace every 5-7 years). The roof should be designed with a drainage slope to prevent water accumulation and corrosion of the steel plate; floor drains should be placed at the lowest point to ensure smooth drainage. In addition, the bottom of the container should be elevated (e.g., using pile foundations) to prevent moisture from eroding the pipelines.
3. Material Selection and Installation Specifications
For water supply pipelines, it is recommended to use PP-R pipes or steel-plastic composite pipes, which are corrosion-resistant and easy to connect; drainage pipes can use UPVC pipes. Pipeline connections should comply with specifications, such as threaded connections for steel-plastic composite pipes below DN50 and groove connections for those above DN50. Water meters are recommended to be installed collectively in outdoor water meter wells or dedicated water meter rooms for easy meter reading and maintenance; if space is limited, remote water meters or IC card smart water meters can be used.
4. Optimization for Special Scenarios
In cold regions, water supply and drainage pipelines should be insulated to prevent freezing and cracking; in humid regions, ventilation design should be strengthened (e.g., installing exhaust fans or skylights) to prevent pipeline condensation. If the container is used in mobile scenarios (e.g., temporary housing on construction sites), flexible connection pipelines should be used to reduce the impact of vibration on the pipelines.