Shanwei Mobile Toilet Specifications
The specifications of mobile toilets in Shanwei can be divided into three categories according to usage scenarios and requirements: single-person standard toilets, double-person toilets, and disabled-accessible toilets, with specific dimensions as follows:

1. Single-Person Standard Toilet
The basic dimensional requirements are a minimum width of 80 cm, a minimum depth of 1 m, and a minimum height of 2 m to meet basic usage space needs. The dimensions of conventional single-person mobile toilets on the market are typically 110 cm in length, 110 cm in width, and 230 cm in height, suitable for short-term use in ordinary public places; mini single-person models have more compact dimensions, being 100 cm in length, 100 cm in width, and 220 cm in height, applicable to scenarios with limited space. The design of these specifications needs to take into account standing, turning, and equipment installation space to ensure user comfort.
2. Double-Person Toilet
The dimensions of double-person toilets need to meet the requirements for simultaneous use by two people, with basic requirements of a minimum width of 1.2 m, a minimum depth of 1.5 m, and a minimum height of 2.2 m. The dimensions of common double-person mobile toilets on the market are 180 cm in length, 110 cm in width, and 230 cm in height. For these specifications, it is necessary to focus on considering the activity space for two people using the toilet side by side to avoid inconvenience due to insufficient space, while also reserving sufficient ventilation and lighting areas.
3. Disabled-Accessible Toilet
The design of disabled-accessible toilets needs to comply with barrier-free standards, with basic dimensional requirements of a minimum width of 1.2 m, a minimum depth of 2 m, and a minimum height of 2.2 m. Mobile toilets adapted to barrier-free needs usually have larger dimensions, generally being 180 cm in length, 150 cm in width, and 240 cm in height. For these specifications, it is necessary to focus on considering the wheelchair turning space (with a diameter of at least 1.5 m), the installation positions of handrails, and the door width (not less than 90 cm) to ensure that disabled individuals can use the toilet independently and safely.
Specification Adjustment Instructions
The above dimensions are general reference values. The actual specifications can be flexibly adjusted according to factors such as the specific usage location (e.g., scenic spots, construction sites, temporary events), the number of users (e.g., peak-hour traffic), and the usage duration (e.g., short-term events or long-term fixed use). For example, mobile toilets for long-term fixed use can have their dimensions appropriately increased to enhance durability, while those for short-term events can reduce their footprint by optimizing the layout.