Quay lại blog
Bài viết

Prefabricated House Roof Waterproofing

Quản trị 18 tháng 9, 2026

Waterproofing for the roof of a prefabricated house requires a systematic renovation plan tailored to its structural characteristics and leakage challenges, strictly adhering to construction specifications and material compatibility requirements.

I. Structural Characteristics and Leakage Challenges

The roof of a prefabricated house is composed of multiple concrete panels joined together, with core leakage risks stemming from the following features:

  1. Panel Joint Issues: Panel joints serve as through-penetration channels for water infiltration, prone to cracking over time due to temperature differentials and settlement, creating pathways for rainwater penetration.
  2. Substrate Defects: The substrate is susceptible to unevenness, sanding cracks, and other issues, causing rainwater to flow across the roof and expand the leakage area.
  3. Dynamic Deformation: The structure undergoes dynamic deformation due to load changes or temperature fluctuations, causing ordinary waterproofing materials to crack and fail under tension or compression.
  4. Weak Gutter Areas: Gutter regions, with concentrated drainage and harsh operating conditions, require specialized weather-resistant waterproofing techniques; otherwise, they are prone to damage from water accumulation or freeze-thaw cycles.

II. Waterproofing Renovation Plan

A comprehensive, systematic treatment process must be adopted, abandoning makeshift methods such as local joint patching or surface coating:

  1. Comprehensive Clearance: Thoroughly remove debris, old waterproofing layers, and loose substrates from the roof to ensure a flat and solid construction surface.
  2. Substrate Repair: Precisely repair unevenness, sanding cracks, and other defects using anti-crack mortar or polymer cement-based materials to enhance substrate stability.
  3. Panel Joint Reinforcement: Deeply reinforce panel joints using rigid filling materials (such as epoxy resin or polymer mortar) to seal through-penetration water channels.
  4. Membrane Waterproofing: Lay national standard thickened polymer-modified bitumen membranes to form a comprehensive waterproofing barrier, with membrane thickness meeting the requirements for Grade I waterproofing (≥3 layers) or Grade II waterproofing (≥2 layers).
  5. Gutter Strengthening: Apply specialized exposed-type waterproofing coatings or membranes in gutter areas to enhance weather resistance and UV resistance, preventing water leakage from accumulation.

III. Construction Specifications and Material Requirements

  1. Specification Compliance: According to the requirements of the General Code for Waterproofing of Buildings and Municipal Engineering, Grade I waterproofing for flat roofs requires at least one layer of membrane waterproofing, while Grade II waterproofing requires two layers.
  2. Material Suitability: Prioritize materials with strong tensile and deformation resistance (such as polymer-modified bitumen membranes) and conduct on-site performance inspections; construction should avoid rainy, snowy days, and winds exceeding Force 5, with temperatures suitable for material application.

IV. Warranty and Maintenance

After project completion and acceptance, a 5-year formal written warranty can be provided, ensuring long-term resolution of recurrent leakage issues through regular inspections and maintenance.