The renovation of prefabricated houses should be systematically carried out from two aspects: structural reinforcement and functional upgrading. The specific methods are as follows:

I. Structural Safety Enhancement

  1. Comprehensive Structural Assessment
    Before renovation, a professional agency should be commissioned to conduct a structural safety inspection, focusing on checking the crack width of prefabricated slabs (grouting repair or carbon fiber reinforcement is required if the width exceeds 0.3 mm), the bolt corrosion rate (replacement is mandatory if it exceeds 30%), and evaluating the connection stability between prefabricated slabs and ring beams.
  2. Slab Joint and Wall Reinforcement
    Remove the original slab joint filling materials, implant φ6 deformed steel bars, and then pour C30 fine aggregate concrete; after removing the old bricks from the exterior wall, perform steel bar implantation and grouting (the steel bar spacing should be ≤ 300 mm), and add anti-crack fibers to the plaster layer to enhance its toughness.
  3. Addition of Structural Columns and Support Systems
    Add 240 mm × 240 mm structural columns at the four corners of the house, using φ6 + φ8 steel bars for binding and anchoring them to the floor slab; during the construction phase, set up steel pipe supports every 1.2 meters along the length of the prefabricated slabs, and use H-shaped steel beams (cross-section ≥ 200 mm × 200 mm) for underpinning at key nodes to ensure structural stability during the demolition phase.

II. Renovation of Key Components

  1. Roof System Update
    After removing the original wooden roof, pour a concrete roof (thickness ≥ 120 mm) while maintaining the building height unchanged, equipped with φ8@150 double-layer bidirectional steel bar mesh inside, apply waterproof coating on the surface, and set up a drainage slope to provide a foundation for subsequent laying of tiles or photovoltaic panels.
  2. Construction Sequence Control
    Follow the principle of 'from the middle to the sides', with the daily demolition area not exceeding 30% of the total floor slab area. Use water drilling for cutting instead of heavy hammer impacts, and simultaneously monitor the stress changes in the support system with strain gauges to prevent uneven settlement of the foundation.

III. Functional Upgrading Plan

  1. Sound Insulation Performance Improvement
    Add 50 mm thick sound insulation cotton (density ≥ 32 kg/m³) to the walls, replace the windows with 6+12A+6 insulated glass, and lay a composite layer of shock-absorbing pads and sound-insulating mortar on the floor slab, which can reduce noise by 30-40 decibels.
  2. Elderly-Friendly and Smart Renovation
    Install elevators in public areas (the foundation bearing capacity needs to be verified), reserve smart home pipeline interfaces indoors, use anti-slip floor tiles and handrails in the bathroom, and lower the kitchen countertop to a height of 750 mm to accommodate wheelchair use.

Acceptance Criteria after Renovation: The structural reinforcement should pass a load test to verify its bearing capacity, the sound insulation effect should meet the standards of the 'Code for Design of Sound Insulation in Civil Buildings' GB50118-2010, and the waterproofing work should undergo a 48-hour closed water test without leakage.