The load conditions of prefabricated houses vary depending on the usage scenario, type of prefabricated panel, and structural parameters, and the load-bearing capacity needs to be determined according to specific conditions.

I. Load Standards Classified by Usage Scenarios
- Residential Scenarios: According to the "Building Structural Load Code", the standard value for live loads in residential rooms is 2.0 kN/㎡, corresponding to an approximate uniformly distributed load of 204 kilograms per square meter, which can cover the needs for daily furniture placement and personnel activities.
- Public Scenarios: The standard value for live loads in public areas such as balconies and corridors is 2.5 kN/㎡, suitable for public activity needs, such as dense pedestrian traffic or temporary stacking of items.
II. Types of Prefabricated Panels and Load-Bearing Capacities
- Concrete Hollow Panels: Commonly found in rural self-built houses or old residential building floors, these panels can bear a uniformly distributed load of 200-250 kilograms per square meter according to national standards. For example, a hollow panel that is 3.6 meters long and 0.6 meters wide (with an area of 2.16 ㎡) has a total load-bearing capacity of approximately 432 kilograms, but concentrated loads should be avoided as they may crack the panel.
- Solid Prefabricated Panels: Due to their dense structure, these panels are often used in areas with heavier loads such as kitchens and bathrooms, and can bear 250-300 kilograms per square meter. Solid panels produced by large factories (with sufficient reinforcement and a concrete grade of C30 or higher) can have a load-bearing capacity of up to 300 kilograms per square meter.
- Prestressed Prefabricated Panels: These panels generate prestress by tensioning high-strength steel wires, offering better crack resistance and load-bearing capacity than ordinary panels. When the span is within 3 meters, they can bear 300-400 kilograms per square meter; when the span exceeds 4 meters, the load-bearing capacity decreases to 250-300 kilograms per square meter, but it is still 20% higher than that of ordinary panels with the same span.
III. Key Factors Affecting Load-Bearing Capacity
- Span: The shorter the prefabricated panel, the stronger its load-bearing capacity. For example, a hollow panel with a span of 2.4 meters can bear 250 kilograms per square meter, while a span exceeding 4.2 meters may only bear 150-180 kilograms.
- Thickness and Reinforcement: A panel that is 10 centimeters thick has stronger load-bearing capacity than one that is 8 centimeters thick; steel bars with a larger diameter (e.g., 8 millimeters) and a smaller spacing (e.g., 15 centimeters) can significantly enhance the load-bearing capacity.
- Type of Load: Uniformly distributed loads (such as sand spreading) are safer, but concentrated loads (such as placing a 300-kilogram safe within 1 square meter) can easily cause panel cracking.
IV. Safety Precautions
- Old Prefabricated Panel Buildings: Prefabricated panels built in earlier years may pose safety hazards due to structural aging or improper renovation (such as the removal of load-bearing walls). It is strictly prohibited to stack additional overweight items (such as large stones or heavy equipment).
- Use of Concentrated Loads: If concentrated heavy objects such as fish tanks or heavy cabinets need to be placed, the concentrated load-bearing capacity of the prefabricated panel should be confirmed in advance. If necessary, reinforcement (such as adding support beams) can be used to enhance safety.