The embedded parts in prefabricated houses mainly include two aspects: the reservation and embedding of electrical pipelines and the positions of embedded wire conduits in floor slabs. Details are as follows:

Reservation and Embedding of Electrical Pipelines

During the design phase, designers need to accurately locate equipment pipelines and generate BIM models together with civil engineering components to provide to prefabricated component factories. Based on the drawings, prefabrication personnel accurately locate and reserve or embed wires, boxes, and conduits in each prefabricated slab and wall according to unified standards.

  • Raw-house Delivery Residences: Most wire conduits are cast into the structural body. The wire conduits and wire boxes within prefabricated walls are cast into shape in one go at the factory along with the structural body. When using composite floor slabs, horizontal wire conduits are laid in the cast-in-place composite layer of the floor slab, which requires on-site wet work. Determining the thickness of the cast-in-place layer of the composite slab should not only consider structural safety but also wiring requirements. If there is a crossover of pipelines, the thickness of the cast-in-place layer should be at least 80mm. Therefore, optimizing the layout of pipelines and reducing pipeline crossovers are key in electrical design, which can reduce the thickness of the structural layer and lower project costs.
  • Reservation of Boxes and Junction Boxes: The boxes and junction boxes reserved in prefabricated components should follow the module of the prefabricated components and be accurately and standardizedly located on the prefabricated components. Socket outlets, switches, weak-current equipment, fire-protection equipment, etc., set on prefabricated walls need to have junction boxes reserved in advance during the design phase. It is advisable to use standard 86-type junction boxes. Lighting fixtures, fire detectors, and other equipment in composite floor slabs need to have deep-type junction boxes reserved to connect with the pipelines in the cast-in-place layer of the composite floor slab. The specific positions of junction boxes should be initially located by the electrical discipline and then precisely located by the structural discipline.

Positions of Embedded Wire Conduits in Floor Slabs

The embedded wire conduits in prefabricated floor slabs are usually laid in slab joints, end recesses of slabs, or local cast-in-place layers.

  • Slab Joint Positions: These are the most common and ideal positions for embedding. During construction, first clean the slab joints, then lay the wire conduits in them, and finally fill them tightly with fine aggregate concrete. This can avoid slotting in the body of the prefabricated slab and does not damage the structural strength and integrity of the floor slab.
  • End Recesses of Slabs: Some types of prefabricated slabs are designed with recesses at both ends during manufacturing. These recesses can be used to place wire conduits, which makes construction convenient and can hide the wire conduits.
  • Local Cast-in-Place Layers: For areas such as kitchens and bathrooms that have waterproof requirements or need to lay floor tiles, a cast-in-place layer is often poured on the prefabricated slab, and wire conduits can be embedded in it. This can meet multi-functional wiring requirements and protect the wire conduits with concrete.