Quay lại blog
Bài viết

Prefabricated House and Earthquake

Quản trị 17 tháng 9, 2026

The performance of prefabricated houses in earthquakes depends on specific circumstances. Overall, their earthquake resistance is limited and influenced by multiple factors such as the construction year, building codes, and construction quality.

1. Earthquake resistance is closely related to the construction year and building codes Prefabricated houses built before 1990 mostly followed the old TJ11-78 earthquake resistance code. The earthquake resistance standards were relatively low, and the “three-level seismic fortification” theory was not clearly defined. In areas with a seismic intensity of 6 degrees, seismic structural measures were generally not required. These houses often lacked key seismic components such as structural columns and ring beams. The prefabricated slabs were directly placed on brick walls without an overall connection, making them prone to problems such as slab joint cracking and slab detachment during earthquakes. After 1990, the implementation of the GBJ11-89 code and subsequent standards clearly required that prefabricated slabs must be connected with a cast-in-place composite layer, and pure bare laying was prohibited. It also mandated the installation of closed ring beams on each floor and structural columns at the four corners and the four corners of stairs, significantly improving earthquake resistance.

2. Earthquake resistance has an upper limit and is affected by construction Prefabricated slab buildings can generally withstand earthquakes up to magnitude 7, with significant differences between houses built in different eras. Houses built in the 1970s and 1980s were only required to withstand magnitude 6 earthquakes according to the standards at that time. Nowadays, new buildings can withstand magnitude 7-9 earthquakes through prestressed technology, but the actual earthquake resistance depends on whether the construction is up to standard. If the steel bar joints are not properly welded, the earthquake resistance will be directly halved. If the house has cracks, it may be the first to collapse in the next earthquake.

3. Structural defects lead to inherent deficiencies in earthquake resistance Prefabricated houses are assembled from prefabricated slabs, resulting in low structural strength and a lack of firmness and toughness. The prefabricated slabs often adopt a hollow design, and the quantity and distribution of steel bars are not as scientific and reasonable as those in cast-in-place houses. When an earthquake occurs, they are difficult to withstand the impact. Even with slight vibrations, over time, cracks will increase and expand, which may eventually lead to the collapse of the entire building.

4. Reinforcement methods are limited, and caution is needed in high-intensity areas Reinforcement methods include attaching steel plates and adding shear walls, which can improve earthquake resistance by 1-2 levels, but their effectiveness is limited in areas with an intensity above magnitude 8. After the Tangshan earthquake, many reinforced buildings collapsed during aftershocks, indicating that reinforcement is not a panacea. After professional evaluation, if the house is located in a high-intensity area or has been severely damaged, priority should be given to demolition and reconstruction.