Thickness Standards for Prefabricated Concrete Houses
There is no unified standard for the thickness of prefabricated concrete houses, but common prefabricated panel thicknesses are 120mm or 150mm, with specific thicknesses determined by usage scenarios, building types, and design requirements.

Common Thickness Ranges
- Rural Residences: Prefabricated panel thicknesses typically range from 12cm to 15cm, primarily 120mm or 150mm, meeting basic load-bearing and cost-balancing needs.
- Industrial Standards:
- Low-rise residences (e.g., 1-3 floors) commonly use 12cm thick prefabricated panels;
- High-rise residences (4 floors and above) require thickening to 18cm to 24cm to enhance structural stability;
- Special scenarios such as underground garages and equipment floors may have prefabricated panel thicknesses up to 40cm to withstand greater loads or resist groundwater pressure.
- Factory Standardized Production: Some prefabricated concrete houses adopt uniform wall thicknesses, such as 15cm (150mm), balancing production efficiency and structural performance.
Basis for Thickness Selection
- Load Requirements: The thickness of prefabricated panels is directly related to their ability to bear live loads. For example:
- Class I panels (120mm) can withstand 1KN/M², suitable for light load areas (e.g., balconies, corridors);
- Class II panels (150mm) can withstand 2KN/M², used for ordinary residential floors;
- In the southwest region, due to frequent earthquakes, the minimum requirement is Class IV panels (thickness may be ≥180mm), capable of withstanding 4KN/M².
- Span and Dimensions: The longer the span of prefabricated panels, the greater the thickness required to avoid deformation. Residential prefabricated panels have a maximum span of 4.2 meters, beyond which customized thickened panels are needed; widths are mostly 500mm or 600mm, with lengths increasing in 300mm increments (e.g., 3000mm, 3300mm).
- Building Type: Low-rise buildings have lower thickness requirements, while high-rise or special-function buildings (e.g., explosion-proof, soundproof) require thickened panels or composite structures to meet demands.
Other Key Parameters
In addition to thickness, the specifications of prefabricated panels also include span, width, length, and load rating, which should be selected based on comprehensive design requirements. For example, ordinary panels can be up to 4200mm long, but their flexural performance must be verified in combination with thickness and span to ensure safety margins.
Summary: The thickness of prefabricated concrete houses should be determined based on specific scenarios, load requirements, and building codes, with a common range of 120mm to 400mm. Design should prioritize referencing local standards and structural calculations.