Dimensions of Movable Partitions for Outdoor Toilets
The dimensions of movable partitions for outdoor toilets vary depending on the specific scenario and toilet type. Below are the size specifications for common scenarios:

Standing Positions for Individual Urinals
The partition panels for standing positions of individual urinals are primarily used to protect privacy, and their height must meet the basic requirement of blocking the line of sight. According to regulations, the height of such partition panels should be no less than 0.8 meters. They are usually made of metal or plastic materials, with a thickness ranging from 10 to 20 millimeters to balance stability and cost.
Partition Panels in Public Restroom Units
In public restrooms, the dimensions of partition panels and doors must balance privacy protection and ventilation needs. The distance between the partition panel and the floor should be controlled between 100 millimeters and 150 millimeters to prevent direct contact between floor stains and the panel while facilitating cleaning. The height of partition panels and doors in Class I and Class II public toilets should be greater than 1.8 meters, while those in Class III public toilets should be greater than 1.5 meters to meet privacy requirements in different usage scenarios.
Internal Partitions in Prefabricated Mobile Toilets
The dimensions of prefabricated mobile toilets directly affect the layout of internal partitions. The length, width, and height of a regular single-person mobile toilet are approximately 1.1 meters × 1.1 meters × 2.3 meters. The internal partitions are usually made of lightweight materials, with a thickness of about 10 to 15 millimeters, and their height is consistent with the overall height of the toilet. For double-occupancy models, the length increases to about 2.5 meters, while the width remains 1.1 meters, and the internal partitions need to be adjusted according to functional zoning. The dimensions of barrier-free mobile toilets are 1.5 meters × 1.8 meters × 2.4 meters, and the internal partitions must reserve space for wheelchair rotation, with a height usually not less than 1.8 meters.
Squatting/Sitting Areas in Portable Cabin Toilets
For the squatting or sitting areas in portable cabin toilets, the recommended net dimensions of a single room are 1.2 meters × 1.5 meters (including the thickness of the partition panel), and the height of the partition panel should be ≥ 1.8 meters to ensure privacy during use. The partition panels are mostly made of moisture-proof board materials, with a thickness ranging from 15 to 20 millimeters to adapt to the usage requirements in outdoor environments.