For Luzhou fireproof container houses, it is essential to focus on aspects such as material fire resistance, electrical safety, fire separation, and safety distances.

Building materials must comply with regulations

Some container board houses use flammable materials like polystyrene and polyurethane foam for their core materials to save costs. These materials have poor fire safety and can be ignited by sparks from electrical welding or cigarette butts. Luzhou fireproof container houses should be made using rock wool boards or fireproof cotton as fillers, achieving an A-grade fire resistance rating or higher to meet fire safety requirements. For example, the Luzhou residential container houses provided by Sichuan Hongwei Steel Structure Company can effectively reduce fire risks if compliant fireproof materials are used.

Electrical safety must be ensured

Electrical circuit failures are a common cause of fires in container houses. For instance, a fire in a container-modified residence in the industrial park of Anci District, Langfang City, was caused by an electrical circuit failure at the switch, which ignited surrounding weeds and led to the fire. Therefore, the wires and cables in Luzhou fireproof container houses should be protected with sleeves, and sockets and switch boxes should be made of metal-plated zinc and installed in an exposed manner. Additionally, simple firefighting equipment should be provided both inside and outside to facilitate timely firefighting in the early stages of a fire.

Fire separation must be properly implemented

If container houses are used for multiple purposes mixed together, such as accommodation combined with production, storage, or business operations in the same connected space without effective fire separation, a fire can easily cause casualties and property damage. Luzhou fireproof container houses should avoid setting up “three-in-one” premises. If unavoidable, strict fire separation, or “hard isolation,” must be implemented between the production, operation, and storage areas and the accommodation area, which can serve as a “life-saving wall” in critical moments.

Safety distances must be maintained

A minimum safety distance of 6 meters must be maintained between container board houses. Fires spread rapidly, and collapse can easily occur within a short time. After collapse, the container board houses, wrapped in iron sheets, make it difficult for firefighting water cannons to penetrate inside, greatly increasing the difficulty of firefighting and rescue operations. Maintaining safety distances provides favorable conditions for firefighting and personnel evacuation in the event of a fire.