The water and electricity installation for container houses should be systematically carried out from four aspects: design planning, pipeline embedding, construction key points, and safety measures, taking into account their modular characteristics:

I. Design and Planning Stage

The water and electricity layout plan should be determined based on the intended use of the container house (such as for office, residential, or commercial purposes). Priority should be given to using 3D modeling technology to optimize pipeline routing through digital simulation, avoiding conflicts during later construction. For example, in container renovations, strong and weak current pipelines are often embedded along walls or ceilings, while water pipelines are laid along floors or side walls to maximize space utilization. For multi-story container composite buildings, vertical pipeline channels need to be planned, such as setting up dedicated pipe shafts or utilizing stairwells for concealed wiring.

II. Pipeline Embedding and Material Selection

  1. Electrical System:

    • Use flame-retardant PVC pipes or metal conduits to protect wires, preventing direct exposure to the metal structure of the container house and reducing the risk of short circuits.
    • Distribution boxes should be independently installed and equipped with leakage protection devices. The load design should consider future capacity expansion needs. For example, in the power distribution plan for container energy storage systems, battery packs, inverters, and distribution boxes need to form independent circuits to ensure electrical safety.
    • For the lighting system, explosion-proof lamps should be preferred, and control switches should be installed near doors for quick power-off during emergencies.
  2. Water Supply and Drainage System:

    • Drainage pipes should be made of PVC-U or HDPE materials, with a slope design of no less than 1% to prevent water accumulation. For example, the installation requirements for rainwater pipes in packing-box houses specify that they should be installed from the bottom and fixed symmetrically with the water inlet holes through bow-shaped stretching.
    • Water supply can be connected to the municipal water network or additional water tanks can be installed. In winter, exposed pipelines should be wrapped with insulation cotton to prevent freezing and cracking.
    • In areas such as bathrooms and kitchens, waterproof sleeves should be pre-embedded, and floor drains should be installed. The floors should be made slip-resistant.

III. Construction Key Points

  1. Foundation Treatment:

    • The foundation should be raised 200-300mm above the ground to prevent rainwater from flowing back. For example, in the customization of non-standard container houses in Shanghai, it is emphasized that the ground level should be higher than the surrounding area, and drainage ditches should be excavated.
    • When embedding drainage pipes, inspection ports should be reserved at the bottom of the container house for easy later maintenance.
  2. Pipeline Connection:

    • For electrical pipeline connections, special wiring terminals should be used and wrapped with insulating tape to avoid loose connections.
    • Water pipe connections should adopt hot-melt or rubber ring sealing processes to ensure no leakage. For example, in the wall panel installation of Farileai prefabricated box houses, metal connecting pieces are used for fixation, and rock wool boards are filled to enhance sealing.
  3. Lightning Protection and Grounding:

    • Outdoor container houses should be equipped with lightning rods, and the metal structure should be connected to the grounding electrode through galvanized flat steel, with a grounding resistance of ≤4Ω.

IV. Safety and Acceptance

  1. Acceptance of Concealed Works:

    • After the laying of water and electricity pipelines is completed, water and electricity tests should be conducted to check the sensitivity of the leakage protection devices and the smoothness of drainage.
    • Use an insulation resistance meter to test the insulation performance of the circuits to ensure no short-circuit risks.
  2. Later Maintenance:

    • Regularly check the aging condition of pipelines, especially the sealing at joints. For example, container energy storage systems need to remotely monitor battery temperature and distribution box load through a monitoring system to promptly eliminate hidden dangers.