Main Power Cable for Container Houses
It is recommended to choose a flame-retardant copper-core cable with a cross-sectional area of over 10 square millimeters for the main power cable of container houses, with specific adjustments based on the circuit type and equipment power. Details are as follows:

1. Basic Specification Requirements
According to the "Code for Electrical Design of Buildings" (GB 50054-2011), the power cables for container houses must be flame-retardant copper-core cables to reduce fire risks and ensure long-term safety. Among them, the cross-sectional area of the lighting circuit should be no less than 2.5 square millimeters, and the cross-sectional area of the socket circuit should be no less than 4 square millimeters. These specifications can meet the daily power needs of ordinary lighting and small appliances (such as mobile phone chargers, desk lamps, etc.), while complying with national mandatory standards.
2. Upgrade Requirements for High-Power Equipment
If high-power equipment such as air conditioners, electric water heaters, and induction cookers are installed in container houses, the power cable specifications need to be recalculated based on the rated power of the equipment. For example, a single 3-horsepower air conditioner has a power of approximately 2.2 kilowatts and an operating current of about 10 amperes. In this case, it is recommended to choose a copper-core cable with a cross-sectional area of 6 square millimeters or larger to avoid overheating of the circuit and potential safety hazards. If multiple high-power devices are used simultaneously, the total load needs to be calculated by a professional electrician, and a margin of 20%-30% should be reserved to ensure long-term stable operation of the circuit.
3. Core Selection Principles for Main Power Cables
As the main power supply line for container houses, the main power cable needs to bear the total current of all circuits. Therefore, a copper-core cable with a cross-sectional area of over 10 square millimeters is recommended. Copper wires have lower resistivity and better electrical conductivity compared to aluminum wires, reducing power loss and heat generation. At the same time, the outer sheath material of flame-retardant cables can form an insulation layer at high temperatures, delaying the spread of fire and buying time for personnel evacuation.
4. Construction and Acceptance Precautions
The power cable should be laid away from heat sources and sharp objects to prevent damage to the insulation layer. The circuit connections should use dedicated terminals and be tightly pressed to avoid local overheating caused by loose connections. After construction, an insulation resistance test (usually not less than 0.5 megohms) and a power-on test should be conducted to ensure there are no short circuits or leakage phenomena. If the container house is a temporary building, the aging condition of the circuit should be regularly inspected, and aging components should be replaced in a timely manner.