Quay lại blog
Bài viết

Container House Grounding Wire

Quản trị 15 tháng 9, 2026

The grounding wire for container houses should be selected from cables with a cross-sectional area of over 16mm², and it should be ensured that the grounding system complies with relevant specifications. Here are the specific details:

Grounding Wire Specification Requirements

According to the lightning protection and grounding requirements for construction sites, the minimum grounding wire for container mobile homes should be a cable with a cross-sectional area of over 16mm². This conclusion is based on common practices and safety standards. In some scenarios, to enhance safety and reliability, multiple cables may be connected in parallel, or cables with a larger cross-sectional area may be chosen. For example, in power systems, grounding wires are usually required to be made of bare copper flexible wires with a cross-sectional area of over 25mm² to effectively protect the safety of workers in case of accidental voltage.

Grounding System Installation Points

  1. Grounding Electrode Installation
    A foundation pit with a depth of 0.8 to 1 meter and a width of about 0.5 meters needs to be excavated. The bottom should be cleared of stones and other debris. Angle iron or galvanized steel pipes should be used as grounding electrodes and driven into the centerline of the soil. Pipe caps can be added at the top to prevent bending. After installation, galvanized flat iron should be laid immediately to avoid trench collapse.

  2. Equipotential Bonding
    All grounding columns inside the container should be equipotentially welded and connected to the non-functional conductive conductors of the container body (such as the metal shell) to form a reliable equipotential. All grounding points should be clearly marked to ensure good contact and avoid the influence of paint, rust, or welding beads on conductivity.

  3. Lightning Protection System Configuration
    A high-quality lightning protection system should be installed on the roof and connected to at least 2 grounding bars through grounding flat steel or round steel. The lightning protection design should comply with the "Technical Code for Lightning Protection of Building Electronic Information Systems" (GB 50343) and the "Design Code for Lightning Protection of Buildings" (GB 50057) to ensure the safety of electrical equipment and personnel in case of lightning strikes.

Precautions in Practical Applications

  • Environmental Adaptability: In areas with large diurnal temperature differences and significant humidity changes (such as Yiqi), hot-dip galvanized container body coatings should be preferred to extend the anti-corrosion life and reduce the risk of grounding system failure due to corrosion.
  • Regular Inspections: The grounding system should be regularly inspected for connection tightness, cable integrity, and grounding resistance values to ensure long-term reliability.
  • Compliance Verification: The specifications and installation methods of the grounding wire should comply with local building electrical codes to avoid safety hazards caused by standard differences.