Quay lại blog
Bài viết

How to Install Mobile Toilets in Chifeng

Quản trị 27 tháng 9, 2026

The installation process of mobile toilets in Chifeng typically follows the core steps of 'positioning - assembly - connection - debugging', as detailed below:

I. Positioning and Site Preparation

Determine the installation location based on site planning and ground flatness, meeting the following conditions:

  1. Ground Firmness: Choose concrete, hardened ground, or compacted soil ground to prevent structural deformation due to foundation settlement.
  2. Drainage Conditions: For flush toilets, reserve drainage pipe interfaces or install septic tanks to ensure sewage discharge complies with the requirements of the 'Mobile Toilet Hygiene Standard' (GB/T 21239-2023).
  3. Spatial Layout: Reserve sufficient operating space (usually a buffer distance of 0.5-1 meter around a single toilet unit) for easy assembly and future maintenance.

II. Assembling the Main Structure

Select the corresponding assembly method based on the toilet type:

  1. Split-type Mobile Toilets:

    • Chassis Installation: Place the prefabricated steel structure chassis steadily at the designated position, adjust it to a level state using a spirit level, and secure the anchor bolts to prevent displacement.
    • Wall Assembly: Insert the sandwich panel wallboards into the chassis slots one by one, and fix them with bolts or clips; apply sealant at the wallboard joints to prevent rainwater leakage.
    • Roof Installation: Cover the roof panel and secure it, checking the roof drainage slope (recommended ≥3%) to avoid water accumulation. Assembly Time: Usually takes 1-2 hours to complete wall and roof installation.
  2. Integrated Mobile Toilets (Box-type Toilets):

    • The factory has completed interior decoration and equipment integration. On-site, simply use a crane to lift the box unit to the predetermined position, adjust it to a level state, and secure it. Assembly Time: Can be shortened to 0.5-1 hour.

III. Connecting Water and Electricity and Installing Equipment

  1. Water and Electricity Pipeline Connection:

    • The power cord should be connected to the main circuit using waterproof connectors and equipped with a leakage protection device.
    • The water pipe connection should use a quick-connector modular design to reduce welding or hot-melt operations and lower the risk of water leakage. Note: This step should be performed by a professional electrician or plumber.
  2. Internal Equipment Installation:

    • Secure the toilet, sink, partition, and other components, adjusting the water pressure of the flushing system to 0.2-0.3MPa.
    • Install lighting fixtures and ventilation equipment (such as exhaust fans), ensuring the circuit load meets the design requirements.

IV. Functional Inspection and Debugging

  1. Flush Test: Flush continuously 3-5 times to check for pipe blockages and the effectiveness of the water seal.
  2. Circuit Inspection: Use a multimeter to test voltage stability and check if the ground wire is reliably connected.
  3. Seal Inspection: Fill the toilet with water to a level 5cm above the ground and observe for 24 hours; no leakage indicates compliance. The overall installation time for an integrated toilet can be shortened to 2-4 hours, while a split-type toilet requires 4-6 hours.

Installation Standard Basis: All steps must comply with the requirements of the 'Mobile Toilet Hygiene Standard' (GB/T 21239-2023) regarding structural strength, sanitary facilities, and environmental protection emissions to ensure safety and hygiene standards are met.