Waterproofing of Cement Prefabricated Houses

Quản trị 18 tháng 9, 2026

Waterproofing of cement prefabricated houses requires comprehensive control from multiple aspects such as design, materials, construction, and maintenance. Here are the specific key points:

I. Waterproof Design and Material Selection Improving moisture resistance relies on a combination of special designs and materials. Waterproof cement reduces water absorption by adding hydrophobic components; polymer-modified mortar enhances bonding and flexibility, reducing the risk of cracks; moisture-proof membranes laid inside foundations or walls effectively isolate groundwater infiltration. Surface coatings such as waterproof paint or epoxy resin form a dense protective layer to block moisture intrusion.

II. Key Waterproof Areas and Material Adaptation Focus on roof joints, wall panel splices, door and window openings, pipe penetrations, and the moisture-proof layer at the bottom of exterior walls.

  • Roof joints: Preferentially use polymer cement-based waterproof coatings, which have strong adhesion to the base layer and excellent weather resistance;
  • Wall panel splices: Self-adhesive polymer-modified bitumen waterproof membranes can adapt to slight structural deformations to prevent leakage;
  • Door and window openings: Polyurethane sealant fills gaps, offering both elasticity and water resistance;
  • Pipe penetrations: Cement-based capillary crystalline waterproof coatings can penetrate into the concrete, forming crystals to block capillary pores;
  • Moisture-proof layer at the bottom of exterior walls: Use a combination of moisture-proof membranes and waterproof mortar to build a double barrier.

III. Construction Techniques and Technical Specifications

  1. Surface cleaning: Thoroughly remove dust and oil stains from the prefabricated roof panels, repair height differences in panel joints, and ensure a flat base layer;
  2. Leveling layer construction: Use 1:3 cement mortar (mixed with 5% waterproofing agent), with a thickness of 20mm and a flatness error of ≤5mm/2m;
  3. Node reinforcement: Apply waterproof coatings and lay non-woven fabric reinforcement layers at gutters, eaves, and other areas to enhance crack resistance;
  4. Membrane laying: Self-adhesive membranes should overlap by 80mm on the long side and 100mm on the short side, laid from low to high areas, and overlapped in the direction of water flow;
  5. Hot-melt edge sealing: Use a torch to heat the membrane overlaps, melting the edges for firm bonding;
  6. End treatment: After trimming the membrane ends, secure them with metal strips (spaced 500mm apart) and seal with sealant to prevent detachment.

IV. Maintenance and Inspection Mechanism Regularly inspect wall, floor, and roof coatings, focusing on defects such as cracks and peeling. Immediately repair any damage with compatible materials upon discovery. Maintain indoor ventilation and use dehumidifiers during humid seasons to control humidity, avoiding long-term high-humidity environments that accelerate material aging.