By 2026, prefabricated panel houses will be gradually managed through inspection, repair, reinforcement, and reconstruction, rather than being demolished all at once. Instead, they will be classified and handled according to their hazard levels.

1. Inspection, Assessment, and Dynamic Monitoring For prefabricated panel houses, a comprehensive inspection should be conducted first, focusing on foundations, load-bearing walls, beams and slabs, roofs, staircases, balconies, and connection points. Check for issues such as unauthorized modifications, long-term leakage, or overloading. Professional assessments will determine the hazard level of the houses:

  • Houses with low risk and generally stable structures will be included in routine maintenance and regularly monitored;
  • Houses with localized hazards will require timely repairs, such as for slab joint cracks or loose connection points;
  • Houses with high hazard levels (e.g., Grade D dilapidated houses) will need to be immediately vacated, personnel evacuated, and reinforced or demolished and rebuilt.

2. Structural Reinforcement and Local Repairs Common issues with prefabricated panel houses are concentrated in slab joints, connection points, load-bearing components, and waterproofing layers. The following measures can be taken for these areas:

  • Slab joint treatment: Fill with high-strength grout or bond carbon fiber sheets to enhance inter-slab connections;
  • Connection point reinforcement: Add steel components or chemical anchors at the connections between beams, columns, floor slabs, and walls;
  • Waterproofing repairs: Redo the roof waterproofing layer and repair exterior wall leakage points;
  • Load-bearing component strengthening: Use pressure grouting to repair wall cracks and reinforce beams and columns with steel mesh plastering.

3. Old Residential Area Renovation If a house is assessed as Grade A or B (structurally safe but with aging facilities), it can be included in old residential area renovation plans:

  • Infrastructure upgrades: Replace aging pipes, repair roof leaks, and rectify fire safety facilities;
  • Elderly-friendly modifications: Install elevators and add barrier-free access;
  • Environmental improvements: Optimize green spaces, add parking spaces, and improve lighting systems.

4. Repair and Reinforcement (Grade C Dilapidated Houses) For Grade C dilapidated houses (locally hazardous but repairable), systematic reinforcement is required:

  • Wall reinforcement: Add structural columns and ring beams, or use steel mesh mortar layers for reinforcement;
  • Beam and column strengthening: Wrap with profiled steel, bond steel plates or carbon fiber sheets to enhance load-bearing capacity;
  • Floor slab reinforcement: Add steel supports or composite layers beneath the slabs;
  • Seismic upgrades: Add seismic brackets and reinforce foundations to meet current seismic standards.

5. Expropriation and Demolition Expropriation procedures will only be initiated under the following circumstances:

  • Public interest needs: Such as road construction, subway construction, or the construction of schools or hospitals;
  • District reconstruction plans: The area where the house is located is included in urban renewal or shantytown renovation projects, with a clear need for demolition and reconstruction. Expropriation must be carried out in accordance with the law to protect the legitimate rights and interests of residents.