Environmental Requirements for Mobile Toilets in Sichuan

Admin 20 de septiembre de 2026

The environmental requirements for mobile toilets in Sichuan cover multiple aspects, including anti-seepage and waterproofing, pollutant discharge compliance, water conservation and environmental protection, fire prevention and electrical safety, as well as land and planning compliance. Details are as follows:

Anti-seepage and waterproofing: The overall waterproof rating of the mobile toilet's enclosure must be no less than IP65. The floor must undergo multi-layer waterproofing treatment and pass a 48-hour closed water test without any leakage. The sewage storage tank or septic tank must be treated for anti-corrosion and anti-seepage, and any leakage of fecal matter that could contaminate soil and groundwater is strictly prohibited, in compliance with the HJ 2029-2013 standard.

Pollutant discharge compliance: If connected to the municipal sewage network, the GB 8978-1996 tertiary standard must be followed. If adopting a non-networked on-site reuse approach (such as for toilet flushing or landscaping), the GB 18918-2002 Class 1 A standard must be met. For zero-discharge fecal matter, the GB 7959-2012 harmless treatment requirements must be satisfied. Odor emissions must comply with the GB 14554-1993 Class 2 standard, and the indoor ammonia concentration must be controlled at ≤0.3mg/m³.

Water conservation and environmental protection requirements: For conventional water-flushing types, the single-flush volume must not exceed 6L, and for water-saving types, it must not exceed 4L. For foam-sealing types, the single-flush water consumption must not exceed 0.1L, and the foaming agent must be biodegradable. For circulating water-flushing types, the water recycling rate must reach over 80%. For microbial degradation types, zero water flushing must be achieved, and the fecal degradation rate must reach over 90%.

Fire prevention and electrical safety: The enclosure material must be Class A non-combustible rock wool sandwich panels, and the use of flammable foam sandwich panels is strictly prohibited. Electrical wiring must be laid through metal conduits, and the distribution box must be equipped with a leakage protection device with an operating current of ≤30mA. Each enclosure must be equipped with no less than two 4kg ABC dry powder fire extinguishers and an independent smoke detector alarm.

Land and planning compliance: It is strictly prohibited to set up mobile toilets in basic farmland, ecological protection red lines, or river management areas. For temporary land use, approval must be obtained from the local natural resources department, and the usage period generally must not exceed 2 years. Placement within urban areas must comply with urban appearance management regulations, and unauthorized occupation of public spaces is not allowed. They can only be used as temporary structures and cannot obtain property rights.