The seismic resistance of prefabricated houses depends on specific circumstances and cannot be generalized.

From the perspective of design specifications: Prefabricated houses built before 1990 generally have weaker seismic performance. They mostly adhere to the old seismic code TJ11 - 78, which has relatively low seismic standards and does not clearly define the 'three-level seismic fortification' theory. In areas with a seismic intensity of 6 degrees, seismic structural measures are generally not required. These houses often lack core seismic components such as structural columns and ring beams. The prefabricated slabs are directly placed on brick walls without overall connections, making them prone to slab joint cracking and slab detachment during earthquakes. After the implementation of the GBJ11 - 89 code and subsequent standards in 1990, it is clearly required that prefabricated slabs must be connected with cast-in-place composite layers, and pure bare laying is prohibited. Additionally, closed ring beams on each floor and structural columns at the four corners and stair corners are mandatory, significantly improving seismic performance.

From the perspective of house age: Prefabricated slab houses can generally withstand earthquakes of around magnitude 6. Old houses built before the 1980s, due to the low standards at that time, can now only withstand earthquakes of up to 6 degrees at most, while newly built ones can reach 7 degrees. However, even new houses have inferior seismic performance compared to reinforced cast-in-place houses because prefabricated slabs are like building blocks, lacking overall integrity and being prone to disintegration.

From the perspective of structural and other factors: Houses with a height of less than 6 floors are safer than high-rise buildings. Brick-concrete wall structures are relatively fragile, while frame structures are better. Houses with deep foundations or piles are less likely to collapse during shaking. Reinforcement measures such as adding steel bars (installing steel frames or pouring concrete in walls and laying steel bar meshes at joints), installing seismic isolation bearings, and using high-ductility cement for wall plastering can enhance seismic capacity.

From the perspective of prefabricated house types: Panel-assembled buildings (a type of prefabricated house) have high strength, light weight, and good resistance to deformation, so their seismic performance is good.

Impact of construction quality: Construction quality also affects seismic performance. Even if the design complies with seismic codes, unauthorized design modifications and shoddy workmanship during construction, such as reducing the number of structural columns and ring beams, or insufficient concrete strength and shortened curing time, will reduce the seismic performance of the house.