Technical Specifications for Prefabricated Houses
Admin 18 de septiembre de 2026
The technical specifications for prefabricated houses cover material, design, construction, and acceptance criteria, with specific requirements as follows:

I. Material Requirements
Main Component Materials
- Prefabricated Wall Panels: Thickness 50-100mm, concrete strength ≥ C30, with built-in φ6@200 bidirectional steel reinforcement mesh, and embedded parts deviation ≤ 5mm.
- Prefabricated Roof Panels: For spans ≤ 4.2m, thickness ≥ 120mm, equipped with φ8@150 longitudinal reinforcement + φ6@200 transverse reinforcement, and load-bearing capacity test load ≥ 1.5 times the design live load.
- Load-Bearing Framework: Steel structural columns use C-section steel (100×50×20×3mm) or square tubes (80×80×3mm), with yield strength ≥ 235MPa, surface hot-dip galvanized (zinc layer ≥ 85μm); connectors are M12 high-strength bolts (Grade 8.8), with tightening torque 45-50N·m.
Auxiliary Materials
- Waterproof Membrane: SBS modified bitumen, thickness ≥ 3mm, tensile strength ≥ 800N/50mm, elongation ≥ 30%.
- Sealant: Silicone weather-resistant sealant, displacement capacity ±25%, bond strength ≥ 0.6MPa.
- Insulation Wool: Centrifugal glass wool, density 48kg/m³, thermal conductivity ≤ 0.042W/(m·K), water repellency ≥ 98%.
- Grouting Material: Non-shrink CGM-4 type, initial flowability ≥ 320mm, 28d compressive strength ≥ 60MPa.
Concrete and Steel Reinforcement
- Main structural concrete grade ≥ C30, main reinforcement diameter ≥ 8mm, spacing ≤ 200mm; seismic resistance must meet Grade 7 requirements.
II. Design Requirements
- Structural Design
- Comply with national building codes, wall thickness: load-bearing walls ≥ 150mm, non-load-bearing walls ≥ 100mm; roof slope ≥ 5%, internal and external corners to have R50mm rounded fillets.
- Function and Layout
- Meet functional requirements, with reasonable spatial layout and aesthetically pleasing appearance.
III. Construction Requirements
- Foundation Construction
- Site compaction coefficient ≥ 0.93, drainage slope ≥ 2%; foundation bearing capacity characteristic value fak ≥ 120kPa; concrete strip foundation curing ≥ 7 days.
- Main Structure Installation
- Lifting equipment rated load ≥ 1.5 times the component's self-weight; installation verticality deviation ≤ H/1000 and ≤ 20mm; joints must pass a 3-hour water spray test (water volume ≥ 2L/(min·m²)).
- Construction Safety
- Strictly adhere to operating procedures to prevent accidents such as falls from heights and object strikes.
IV. Acceptance Criteria
- Process acceptance shall be conducted in stages to ensure compliance with design requirements.
- Special environmental adaptability: Pass Grade 7 seismic test, with wall material combustion performance reaching Class A.
Note: Technical parameters should be adjusted according to project geological conditions, and it is recommended to commission a professional institution for verification.