Requirements for Steel Frame Structure of Prefabricated Houses

Admin 18 de septiembre de 2026

The steel frame structure of prefabricated houses must meet various requirements in terms of materials, design, construction, corrosion and fire protection, as well as installation and acceptance. Details are as follows:

Material Requirements: For load-bearing structures, Q235 or Q345 grade hot-dip galvanized/aluminum-zinc coated steel should be preferred, with a zinc coating thickness of no less than 180g/m² for corrosion resistance. Key components require re-testing of mechanical properties such as yield strength and tensile strength. The welding material model must match the base material, and baking records should be archived. High-strength bolts must be accompanied by quality certification documents and can only be used after re-testing the torque coefficient or pre-tension for compliance.

Structural Design and Safety: Static and live loads must be strictly distinguished, and load combination calculations should be performed according to specifications to ensure sufficient load-bearing capacity. The layout of the support system should be reasonable and redundant to avoid localized stress concentrations. For newly added attic floors, the vertical load-bearing capacity of wall load points must be calculated, and stiffness and lateral stability must be checked, with deformation limits specified in the drawings. The design service life should reach 50 years, and the main structure should be able to withstand earthquakes of magnitude 8-9 (depending on the design) and typhoons below magnitude 12, with durability relying on corrosion protection layers and regular inspections.

Construction Process Control: During fabrication, errors in layout and the flatness of cutting surfaces must comply with standards. During assembly, fit-up gaps and misalignment should meet requirements, and the temperature for flame straightening must not exceed limits. In welding processes, Class I welds require 100% ultrasonic testing supplemented by magnetic particle inspection, and multi-layer welds require cleaning of slag and control of interpass temperature. Initial, intermediate, and final tightening of high-strength bolts must be completed within specified time frames, with final tightening torque calculated according to formulas.

Corrosion and Fire Protection: The thickness of hot-dip galvanized layers and coating intervals must meet standards. Load-bearing steel structures should be painted with fire-resistant coatings, and walls should be filled with Class A non-combustible insulation materials (such as rock wool), covered with calcium silicate boards or gypsum boards, achieving an overall fire resistance rating of Class II. Electrical wires inside walls must be run through flame-retardant conduits, and unauthorized drilling to damage fire protection structures is strictly prohibited.

Installation and Acceptance: The strength of foundation concrete must reach a certain proportion of the design value, with deviations in anchor bolt displacement and elevation controlled within specified limits. During lifting, the load on a single machine must not exceed limits, and temporary fixing measures should be removed after permanent connections are completed. Final acceptance must verify verticality deviations, overall spatial stiffness, and compliance with design and specification requirements through deflection testing.