The standards for rebar in prefabricated houses should be determined based on different components and design requirements, as detailed below:

I. Prefabricated Floor Slabs

  1. Rebar Diameter:

    • For small spans (up to 3 meters), diameters of 6mm to 8mm are commonly used; for medium spans (3-6 meters), diameters of 8mm to 10mm are required; for large spans (over 6 meters) or high loads (such as commercial buildings), diameters of 10mm to 12mm or even larger are needed.
    • In residential buildings, for spans less than 4 meters, the main rebar diameter is typically 8-12 millimeters; for spans of 4-6 meters, the main rebar diameter is increased to 12-16 millimeters.
    • For old prefabricated slabs, the rebar diameter ranges from 6-16 millimeters, with 6-10 millimeters commonly used for light structures or stirrups, 10-12 millimeters prevalent in multi-story buildings, 12-14 millimeters suitable for medium-load components, and 16 millimeters and above used locally only when special load requirements are present.
  2. Rebar Type:

    • Hot-rolled ribbed rebar (HRB400) is preferred for main rebar due to its high strength and good ductility; hot-rolled plain rebar (HPB300) is generally used for distribution rebar.
    • For large-span floor slabs, prestressed rebar (such as steel strands) should be used to reduce deflection and cracks.
  3. Rebar Spacing:

    • The spacing of main rebar is typically 100-200 millimeters, while the spacing of distribution rebar is 200-300 millimeters.
    • According to the "Code for Design of Concrete Structures" (GB 50010), rebar spacing should be determined through structural calculations, and in seismic-fortified areas, rebar spacing should be increased or the rebar ratio should be increased.
  4. Anchorage and Lap Length:

    • When the concrete strength grade is C20-C30, the anchorage length of HRB400 rebar is approximately 35-40 times the rebar diameter, while that of HPB300 rebar is 25-30 times the rebar diameter.
    • The lap length of rebar should be multiplied by a coefficient based on the anchorage length, with the specific coefficient determined by the percentage of joint area.

II. Other Components

  1. Structural Columns:

    • Four threaded rebars with diameters of 12-14 millimeters are used for the main rebar (14 millimeters are recommended for the corners), and the upper and lower ends should extend into the ring beam by 15-20 centimeters.
    • Round rebars with diameters of 6-8 millimeters are used for stirrups, with a spacing of 10-15 centimeters, and the spacing is increased to 10 centimeters within 50 centimeters of the upper and lower ends of the column.
  2. Ring Beams:

    • Four threaded rebars with a diameter of 12 millimeters are used for the main rebar, arranged in two layers on the upper and lower sides.
    • Round rebars with a diameter of 6 millimeters are used for stirrups, with a spacing of 20 centimeters, and the spacing is increased to 10 centimeters at the corners.