In the context of rural self-built houses, there are two mainstream methods for moisture-proof treatment of prefabricated house foundations: laying moisture-proof membranes and creating prefabricated slab elevated floors.

Laying Moisture-Proof Membranes

  • Principle: High-density polyethylene films (PE films or geotextile membranes) are used to block the upward movement of moisture from the ground.
  • Specific Method: After backfilling and compacting the foundation, first lay a layer of fine sand and gravel on the surface, compact it, and level it. Then, lay the moisture-proof membrane. Finally, pour a 10-centimeter-thick concrete cushion or floor slab on top of the membrane.
  • Advantages: Low cost, with only one or two thousand yuan needed for a whole house; simple construction and short construction period.
  • Disadvantages: Limited durability. If there are sharp stones in the backfill or the membrane is torn during construction, moisture can penetrate. In cases where the house site is in a low-lying area, the groundwater level is high, or rainwater backs up during the rainy season, relying solely on the membrane may not be able to withstand the continuous moisture pressure, and the ground floor may still become damp.
  • Precautions: Choose PE moisture-proof membranes or geotextile membranes produced by regular manufacturers, with a recommended thickness of over 0.15 millimeters. Use clean plain soil for foundation backfilling, without sharp objects. The overlapping part between membranes should be no less than 15 centimeters. Seams should be repeatedly pasted with waterproof tape. Corners should be cut and fitted properly, and the membrane should be turned up at least 10 centimeters along the walls. After laying the moisture-proof membrane, pour the concrete as soon as possible.

Creating Prefabricated Slab Elevated Floors

  • Principle: "Exchange space for dryness" by leaving a 30 - 50 centimeter cavity between the foundation and the ground floor. Underground moisture rises into the cavity and dissipates, unable to reach the ground floor.
  • Specific Method: After pouring the ground beams, control the height of the backfill to be 30 - 50 centimeters from the ground level and compact the backfill.

In addition, for old prefabricated slab houses in urban areas, key points for foundation inspection include: checking for obvious settlement marks on the ground around the house and whether there are height differences between the indoor and outdoor ground; observing whether there are diagonal cracks at the bottom of the walls caused by uneven foundation settlement.