Specifications for Prefabricated Concrete Houses
The specifications for prefabricated concrete houses cover dimensions, component parameters, allowable deviations, and appearance quality requirements, as detailed below:

I. Common Dimensions
Single-story houses are primarily in the form of length × width, with common dimensions of 6m × 3m, 8m × 3m, 10m × 3m, and 12m × 3m. The width ranges from 3 to 6 meters, the height from 2.5 to 5 meters, and the length can extend to tens of meters. Multi-story houses are represented by length × width × height, such as 7.2m × 3.3m × 3.0m and 8.1m × 3.3m × 3.0m. The total height for a two-story house is 4 to 6 meters (2.5 to 3 meters per floor), and for a three-story house, it is 6 to 9 meters (2.5 to 3 meters per floor).
II. Specific Component Parameters
- Prefabricated Concrete Panels: For residential use, the span is mostly 4.2 meters (customization required for longer spans). The width is primarily 500mm or 600mm, and the thickness is commonly 120mm or 150mm.
- House Components: The wall thickness is ≥150mm, and the eave length is adjustable from 0 to 1200mm.
III. Allowable Dimensional Deviations
- Length Deviation: ±10mm for lengths ≤6000mm, and ±15mm for lengths >6000mm.
- Width Deviation: ±25mm for widths ≤6000mm, and ±20mm for widths >6000mm.
- Height Deviation: ±15mm regardless of whether the length exceeds 6000mm.
- Wall Thickness Deviation: -2mm to +5mm.
- Flatness: Lateral bending and warping ≤20mm.
- End Face Tilt: ≤5mm.
- Door and Window Position Deviation: ±15mm.
- Embedded Part Position Deviation: ±5mm.
- Lifting Ring Exposed Height Deviation: ±10mm.
- Protective Layer Thickness Deviation: -2mm to +5mm.
IV. Appearance Quality Requirements
- Cracks: No cracks penetrating the wall thickness are allowed on the surface. Cracks with a width >0.20mm or depth >3mm on the inner or outer surface (excluding surface crazing and mortar shrinkage cracks) must be treated.
- Local Damage: Repair is allowed if the damaged area is ≤1/50 of the outer surface area and the steel reinforcement framework is not exposed.
- End Face Tilt: The tilt must be ≤5mm.
- End Face Impact Damage: Repair is allowed if the longitudinal length is ≤100mm and the transverse width is ≤50mm.
- Surface Flatness: The local concave-convex depth must be ≤5mm.
- Honeycombing, Pitting, and Adhesion: Repair is allowed if the adhesion depth is ≤10mm and the total area is ≤8% of the inner/outer surface area.
- Joint Leakage: Repair is allowed if the leakage depth is ≤ the protective layer, the length of a single leak is ≤300mm, and the cumulative length is ≤10% of the house length.
All parameters must strictly adhere to design specifications to ensure structural safety and functionality.