The rebar layout for precast slab houses should be determined based on the type of precast slab and design requirements. The specific layout methods are as follows:

1. Precast Hollow Slabs
- Main Tension Rebars: Located in the tension zone at the bottom of the slab, typically equipped with 4-8 hot-rolled rebars (such as HPB300 or HRB400), with diameters ranging from 6-12mm. The quantity is determined by the slab width (600-1200mm) and span (3-6m). For example, a hollow slab with a width of 1200mm and a span of 4m may be equipped with 6 main rebars with a diameter of 8mm.
- Distribution Rebars: Used to resist temperature and shrinkage stresses, these rebars have a diameter of 6-8mm and are spaced 150-300mm apart, arranged along the width of the slab.
- Prestressed Rebars: If prestressing technology is used, 2-4 high-strength steel strands (with diameters of 9.5-15.2mm) may be employed, partially or fully replacing the main tension rebars to enhance crack resistance.
2. Precast Solid Slabs
- Bidirectional Tension Rebars: Tension rebars are arranged in both the longitudinal and transverse directions of the slab, typically at a density of 6-10 rebars per meter, with diameters of 8-12mm, forming a bidirectional tension network.
- Structural Rebars: These rebars have a diameter of 6-8mm and are spaced 200-300mm apart to control crack width and improve durability.
- Additional Rebars: In areas of concentrated stress (such as supports), 2-4 additional rebars may be added to enhance local load-bearing capacity.
3. Special-Purpose Precast Slabs (such as bridge deck slabs and wall panels)
- More Main Rebars: For example, bridge precast slabs may be equipped with 10-20 main rebars (with diameters of 10-16mm), supplemented by dense distribution rebars and shear rebars (such as stirrups) to meet complex stress requirements.
- Shear Design: In areas with high shear forces (such as beam-slab connections), stirrups should be densified, with spacing possibly reduced to 100-150mm and diameters of 6-10mm.
4. Rebar Layout Requirements for Self-Built House Precast Slabs
- Prestressed Rebars and Concrete Strength: Prestressed rebars must be used, and the concrete strength should not be lower than C30. The specifications and quantity of rebars should comply with national standards (such as GB 50010 'Code for Design of Concrete Structures').
- Double-Layer Bidirectional Rebar Layout: The floor slab can be arranged in a double-layer bidirectional manner, with rebars in both the x and y directions on the bottom slab and top slab. Rebars in the short-span direction are placed on the lower layer, while those in the long-span direction are on the upper layer; for cover rebars, the opposite is true, with long-span rebars on the lower layer and short-span rebars on the upper layer. Face rebars and cover rebars are arranged orthogonally to form a bidirectional tension network, effectively preventing floor slab cracking and water seepage.
Precautions: In actual engineering projects, the rebar layout should be determined in combination with design drawings, load requirements, and construction specifications. It is strictly prohibited to arbitrarily reduce the quantity or diameter of rebars to ensure structural safety.