There are some prefabricated panel houses in Linfen, with varying situations in different residential areas, and these prefabricated panel buildings have certain safety hazards. Details are as follows:

Situation of some prefabricated panel houses in Linfen

  • Railway Dormitory Community: Located at No. 1, Tiewei Lane, Chezhan Community, Chezhan Street, it was built between 1979 and 1999. The structure consists of prefabricated panel buildings, with a total of 49 buildings. According to a third-party assessment in 2022, there are 2 buildings rated as Class D, 44 buildings rated as Class C, and 3 buildings rated as Class B. For the Class C and D buildings, the Chezhan Street Sub-district Office has organized the community to strengthen inspections, hang warning signs, inform residents of the risks, strengthen supervision and control, and carry out irregular inspections, especially observing the building conditions during extreme weather and special circumstances. A public opinion survey on the renovation of dilapidated buildings was conducted from March 12 to 19, 2025, and the results have been reported. However, as of April 24, 2025, the Chezhan Street Sub-district Office has not received any relevant renovation or demolition notices.
  • Yejian New Development Area: Buildings 1 - 15 are prefabricated panel houses, built around the 1990s. Some roofs have cracks, posing safety hazards. Among them, Buildings 1 - 13 (public housing) were approved for shantytown renovation projects in 2018, while Buildings 14 - 15 are small-property houses and have not been included in the shantytown renovation projects yet.
  • Prison Buildings 2 and 3 of Linfen Prison: These are prefabricated panel houses, and a reinforcement project is currently underway. The budget amount and the maximum price limit for the procurement project are both 1,876,489.43 yuan, and the contract performance period is 180 calendar days.

Safety hazards of prefabricated panel buildings

  • Floor panel issues: There are gaps between the panels. If the construction treatment is improper, building settlement may lead to problems such as floor panel cracking and water leakage.
  • Risk of uneven stress: It is not advisable to build partition walls randomly on the floor panels; otherwise, uneven stress may cause the floor panels to collapse.
  • Poor seismic performance: In the past, rural house construction lacked scientific design and had simple construction techniques. Building prefabricated panels directly on brick walls buried serious safety hazards and reduced the seismic performance of the houses.