Electrical Design of Container Houses

Admin 15 de septiembre de 2026

The electrical design of container houses requires a comprehensive consideration of equipment integration, wiring specifications, safety protection, and system coordination to ensure both functionality and safety.

1. Equipment Integration and Cabin Design

The core of electrical design for container houses is to integrate high-voltage switchgear, low-voltage distribution cabinets, transformers, and other equipment into customized cabins, following electrical logic to optimize layout. For example, prefabricated cabin-mounted cabinets are manufactured in a factory setting, completing equipment installation, wiring, and joint debugging before being transported as a whole. On-site, only foundation placement, busbar connection, and cable crimping are required for commissioning. This design necessitates coordination among multiple disciplines, including structural, electrical, and HVAC, to ensure reasonable equipment spacing and avoid short circuits or electric leakage risks.

2. Wiring Specifications and Insulation Requirements

Electrical wiring should use outdoor-type cross-linked polyethylene insulated flame-retardant cables with different color codes, featuring independent insulation and sheath layers. The long-term operating temperature should be no less than 105°C, and the insulation withstand voltage should exceed the actual voltage level. Insulated walkways within the container should be covered with flame-retardant insulating mats with an insulation voltage of ≥5kV, neatly trimmed to cover gaps between equipment cabinets. Additionally, the design of distribution boxes should consider three-phase balance to avoid safety hazards caused by load imbalance.

3. Safety Protection Systems

1. Grounding and Lightning Protection
All grounding posts should be equi-potentially welded and connected to the metal shell of the container to form a reliable grounding system. The roof should be equipped with a lightning protection system, connected to at least two grounding bars via grounding flat steel or round steel. The lightning protection design should comply with the "Code for Design of Lightning Protection of Buildings" (GB 50057). If the container is outside the original lightning protection coverage area, a separate lightning protection device should be installed.
2. Fire Protection and Emergency Lighting
The container should be equipped with an emergency lighting system that activates immediately upon power failure, with luminous flux meeting the requirements of the "Code for Design of Fire Emergency Lighting and Evacuation Indicating Systems" (GB 17945). It should also be equipped with a fire protection system, using explosion-proof luminaires (with an IP rating of IP65 or higher) and temperature-controlled ventilation devices to ensure controllable fire risks.

4. Intelligence and Expandability

Electrical design should reserve intelligent interfaces to support remote monitoring and data collection. For example, container energy storage systems should integrate battery management systems (BMS), energy management systems (EMS), and dynamic environment monitoring systems to achieve real-time monitoring of equipment status and fault warnings. Additionally, the design of distribution boxes should consider future load growth and reserve expansion space to avoid repeated modifications.