The specifications of mobile toilets in Chuxiong community vary depending on the type and functional requirements. Common specifications are as follows:

I. Basic and Single-Toilet-Cubicle Specifications Most basic mobile public toilets adopt a standardized design, with dimensions of 1.1 meters in length, 1.1 meters in width, and 2.3 meters in height, balancing portability and space utilization. They are suitable for public places with low pedestrian density. The floor area of single-toilet-cubicle mobile public toilets is usually 1.2㎡ to 1.8㎡, with an internal net size of 1.2m to 1.5m in length × 1.0m to 1.2m in width, and a height between 2.2m and 2.5m, meeting basic toilet needs. They are commonly found at temporary events or in small communities.

II. Multi-Toilet-Cubicle Combination Specifications Double-toilet-cubicle mobile public toilets occupy an area of approximately 3㎡ to 4㎡. For three or more toilet cubicles, the floor area needs to be increased according to the number, with each additional toilet cubicle adding about 1.5㎡ to 2㎡. The overall length is mostly between 3m and 6m, and the width is 1.5m to 2.5m, suitable for areas with high pedestrian flow. For such toilets, it is necessary to plan the internal passages reasonably to ensure ease of use.

III. Extended Specifications for Special Scenarios Some models adjust their dimensions to meet special requirements. For example, the length may exceed 1.5 meters, but it should be noted that overly large dimensions may affect mobility. The dimensions of management rooms or accessible toilet cubicles may be extended to 2.46 meters in length and 1.4 meters in width, with a height maintained between 2.1 meters and 2.5 meters to accommodate equipment or barrier-free facilities.

IV. Detailed Specifications for Functional Zones

  1. Accessible Toilet Cubicles: They must comply with the Code for Accessibility Design. The internal net size should be no less than 1.8m × 1.4m. An accessible ramp with a width of no less than 0.8 meters should be installed at the entrance, and space should be reserved inside for wheelchair rotation.
  2. Baby Care Rooms/Third Toilets: The area should be no less than 4㎡, with a net width of no less than 1.5 meters. They should be equipped with baby care tables, children's toilets, and other facilities to ensure sufficient operating space.
  3. Toilet Cubicle Parts: The internal dimensions of a single toilet cubicle are 0.645 meters in length, 0.545 meters in width, and 0.2 meters in height, suitable for compact designs.
  4. Management Rooms: The standard dimensions are 2.46 meters in depth, 1.4 meters in width, and 2.1 meters in height, used for storing cleaning tools or monitoring equipment.
  5. Accessible Toilet Cubicles: Their dimensions are similar to those of ordinary toilet cubicles, but they need to be additionally equipped with barrier-free facilities such as handrails and emergency call devices.

The above specifications should be selected comprehensively based on the actual usage scenario, pedestrian density, and functional requirements to ensure the practicality and compliance of the mobile toilets.