Specifications for Cement Prefabricated Houses

Admin 18 de septiembre de 2026

The specifications for cement prefabricated houses cover requirements for building materials, structural design, construction techniques, acceptance inspections, and other related aspects, as detailed below:

Building Material Standards: Cement must comply with GB 175-2007 'General Purpose Portland Cement'. Reinforcing steel bars should meet the requirements of GB/T 1499.2-2018 'Steel for Reinforced Concrete - Part 2: Hot-Rolled Ribbed Bars'. Aggregates must adhere to GB/T 14684-2011 'Sand for Building' and GB/T 14685-2011 'Pebble and Crushed Stone for Building'. The concrete strength grade of prefabricated components should not be lower than C30, with load-bearing wall panels requiring a grade of C35 or above. The standard compressive strengths are 30MPa (C30) and 35MPa (C35), respectively. The diameter of main reinforcing bars should be ≥8mm, with a spacing ≤200mm, and a protective layer thickness ≥20mm (≥25mm in exposed environments), in accordance with the 'Code for Design of Concrete Structures' (GB 50010-2010).

Structural Design Standards: Compliance with GB 50010-2010 'Code for Design of Concrete Structures' and GB 50009-2012 'Load Code for the Design of Building Structures' is required to clarify the load-bearing capacity, seismic performance, and durability requirements of prefabricated components. In seismic fortification intensity zones of 6 degrees, the requirement of 'no damage under minor earthquakes' should be met, while zones of 7 degrees or above require special calculations (as per the 'Code for Seismic Design of Buildings' GB 50011-2010). Node connections should use embedded part welding or high-strength bolts, with a bolt tensile strength ≥8.8 grade. The dimensions, reinforcement, and connection methods of the main structure must meet seismic fortification requirements.

Construction Technique Standards: Based on GB 50666-2011 'Code for Construction of Concrete Structures' and JGJ 1-2014 'Technical Specification for Prefabricated Concrete Structures', the production, transportation, lifting, and connection of prefabricated components should be standardized. The length error of wall panels should be controlled within ±3mm, with a thickness error of ±2mm; the position deviation of door and window openings should be ≤5mm. The construction process includes foundation treatment, foundation construction, component installation, and roof waterproofing works.

Acceptance Inspection Specifications: Inspections should be carried out in accordance with GB 50204-2015 'Code for Acceptance of Construction Quality of Concrete Structures', checking component size deviations, appearance quality, and strength. Each batch of components should undergo compressive and impermeability tests, with a sampling ratio ≥5% and an impermeability grade ≥P6 (no leakage under 0.6MPa water pressure). During on-site acceptance, the perpendicularity deviation should be ≤h/1000 (h being the wall height) and ≤10mm; joint waterproofing should use elastic sealant, with a width ≥15mm and a peel strength ≥0.5MPa.

Other Specifications: The thermal conductivity of exterior wall panels should be ≤0.24W/(m·k). Sandwich panels commonly use 50mm-thick expanded polystyrene foam (EPS) or rock wool layers, meeting the 'Code for Thermal Design of Civil Buildings' (GB 50176-2016). Wastewater discharge should comply with the 'Integrated Wastewater Discharge Standard' (GB 8978-1996), with a pH value of 6~9 and suspended solids ≤70mg/l.