The evaluation plan for cement prefabricated houses should be comprehensively designed from six dimensions: structural safety, construction efficiency, economic and environmental performance, appearance and durability, policy and regional adaptability, and testing methods. Details are as follows:

I. Structural Safety Performance Evaluation
It is necessary to verify the seismic fortification intensity through professional institutions (e.g., a seismic intensity of 7 degrees can withstand an earthquake of magnitude 8), check whether the wall crack width is ≤0.2mm; verify the stability of the module connection method (e.g., prestressed bolts) under a typhoon of intensity 12, and test the anti-uplift capacity of the roof waterproofing membrane; detect whether the fire resistance limit of the concrete is ≥3 hours; and conduct long-term monitoring of the foundation settlement (the probability of exceeding the standard within 5 years for houses without secondary reinforcement is 37%).

II. Construction Efficiency and Quality Evaluation
Compare the prefabrication stage (7 days required for single-module production in the factory) with the on-site installation time (1 day for assembling a 100㎡ house), and compare the construction period with that of traditional brick-and-mortar structures (3-6 months); check the standardization of the factory production process (steel bar binding, concrete pouring, steam curing); investigate the risk of micro-cracks during low-temperature construction (temperature < 5°C), the accident rate of cement board cracking (e.g., losses exceeding 8 million yuan in a case in a county in Jiangxi), and calculate the amount of construction waste generated (90% less than traditional methods).

III. Economic and Environmental Performance Evaluation
Analyze the main construction cost (30%-32% savings compared to brick-and-mortar structures) and the life-cycle cost (maintenance costs after 15 years may reach 25% of the initial investment); evaluate carbon emissions (41% lower than traditional buildings), the proportion of recycled aggregate used (required to be ≥28%), and the construction waste recycling rate (target ≥92%).

IV. Appearance and Durability Evaluation
Detect the wall color difference rate caused by ultraviolet radiation (15%-20% after 5 years); test the frost resistance (mass loss ≤5% after 25 cycles), water permeability resistance (no leakage under 0.8MPa water pressure for 24 hours), and the deviation in the thickness of the steel bar protective layer (≤±5mm).

V. Policy and Regional Adaptability Evaluation
Check whether it complies with local subsidy standards for prefabricated buildings (e.g., 80-120 yuan per square meter); verify winter construction techniques for the Northeast region, and pilot the "cement house + photovoltaic" system in rural markets (e.g., cost savings of 180,000-250,000 yuan per household for a 6-story residential building in a county in Zhejiang).

VI. Testing Methods and Basis
Use instruments to measure dimensions, flatness, and crack width (in accordance with GB 50204-2015); test compressive strength (C30 concrete must be ≥30MPa), flexural strength (floor slabs must be ≥4.5MPa); and commission a CMA-certified testing institution to issue a legally valid report.