Toilet Wall Movement by 0.3 Meters
The movement of a toilet wall by 0.3 meters requires a comprehensive assessment based on technical specifications and actual conditions. Currently, there are no unified standard cases, but the following core principles need to be emphasized:

1. Space Dimensions Must Meet Basic Usage Requirements
According to general decoration standards, sufficient operating space must be reserved for toilet installation: The distance from both sides of the toilet to the wall should be no less than 0.3 meters, and the distance from the front end to the wall should be no less than 0.4 meters. If the movement of the wall results in insufficient spacing between the toilet and surrounding walls, it may affect daily use (such as restricted movements during cleaning and standing up) and even violate building safety standards. For example, if the original bathroom width is only 1.5 meters, moving a single wall by 0.3 meters may leave a remaining width of less than 1.2 meters, which is difficult to meet the requirements for toilet installation and passage.
2. Drainage System Modifications Require Careful Assessment
Toilet drainage pipes (such as toilet drainage pipes and floor drain pipes) are usually designed in a fixed manner. Moving the wall may involve re-layout of the pipes. If the original drainage pipes are of the sunken box type or same-floor drainage, modifications are relatively easier. However, if they are cross-floor drainage (pipes passing through the ceiling of the downstairs neighbor), it is necessary to obtain the consent of the neighbors and avoid damaging the original slope, otherwise, blockages or odor problems may occur. In addition, sufficient inspection ports should be reserved for the new drainage pipes to facilitate later maintenance.
3. Waterproofing is a Key Safety Link
The waterproofing height of bathroom walls should be adjusted according to the dry-wet separation situation: If dry-wet separation is not implemented, it is recommended that the waterproofing in the shower area be up to 1.8 meters, and at least 0.3 meters in other areas. After moving the wall, special attention should be paid to the joints between the new wall and the original floor and wall:
- Base layer cleaning: Remove the original waterproofing layer to the structural layer to ensure there is no dust or oil stains;
- Application of waterproofing coating: Use flexible waterproofing materials (such as polyurethane) and apply 2-3 coats with a thickness of no less than 1.5 millimeters;
- Closed water test: After the waterproofing layer is dry, a 48-hour water filling test should be conducted to observe whether there is any leakage on the ceiling downstairs.
4. It is Advisable to Consult a Professional Team First
The movement of a toilet wall involves various aspects such as structural safety and water and electricity modifications. It needs to be comprehensively designed based on the specific house structure (such as the location of load-bearing walls), drainage method (same-floor/cross-floor), and usage requirements. Ordinary homeowners find it difficult to comprehensively assess the risks. It is recommended to entrust a certified designer to issue a plan and have it operated by a qualified construction team to avoid rework or safety hazards due to improper operations.