Toilet Wall Moved 30cm
The toilet wall is moved 30cm towards the master bedroom. Plan 2 and Plan 3 are more recommended. Here is a detailed analysis:

Plan 2: Move the right wall of the toilet 30cm towards the bedroom and adjust the toilet door to the right-hand side of the entrance to the master bedroom. Design two built-in wardrobes on the right side of the bed and at the foot of the bed, with the wardrobe at the foot of the bed having a depth of 55cm. The two corners of the wardrobes at the entrance adopt beveled designs. This plan significantly increases storage capacity by optimizing the spatial layout. The width of the passage from the foot of the bed to the wardrobe is about 65cm, which can meet basic passage needs. To address the possible sense of oppression caused by the wardrobe directly facing the entrance, it is recommended to hang space-extending decorative paintings on the wall where the wardrobe faces the entrance to alleviate the cramped feeling through visual guidance. This plan has a relatively small impact on the internal layout of the bathroom, only requiring the adjustment of the door position without modifying the original piping system.
Plan 3: Similarly, move the right wall of the toilet 30cm towards the bedroom, but the upper wall needs to be moved down 50cm in sync with the master bedroom door. Design a full-wall wardrobe with a depth of 55cm at the foot of the bed. This plan has the strongest storage capacity, but the bathroom space is significantly compressed. Due to space constraints, it may not be possible to install a traditional partition in the bathroom, and a shower curtain needs to be used instead for dry-wet separation. The waterproofness and privacy of the shower curtain are slightly inferior to those of a fixed partition, and it needs to be replaced regularly and kept well-ventilated to avoid mold growth caused by moisture. This plan has no special requirements for the piping layout, but it is necessary to ensure that the moved wall is not a load-bearing structure and to carry out proper waterproofing during construction.
Construction Precautions: If the toilet partition wall is not a main load-bearing wall and the sewage pipes have not been modified, moving it 30cm usually does not require the consent of the downstairs neighbors, but it is still necessary to strictly follow building codes. Waterproofing is crucial. After moving the wall, reapply waterproof coating to a height of at least 1.8 meters and conduct a 24-hour closed-water test. Use special sealant at pipe connections to avoid leakage risks. In addition, moving the wall may affect indoor lighting, which can be compensated for by adding auxiliary lighting or using light-colored decorative materials.




