The installation of temporary mobile plastic toilets must be carried out strictly in accordance with standardized procedures to ensure safety and functionality meet the required standards. The specific steps are as follows:

I. Pre-installation Preparations
Site Survey
- Determine the installation location in advance, prioritizing flat and solid ground areas while avoiding main construction roads, pollution sources, and areas prone to water accumulation.
- If near construction areas such as foundation pits, it is recommended to maintain a distance of more than 1.5 meters from the edge of the foundation pit to prevent construction vibrations or collapses from affecting the stability of the toilet.
Material Verification
- Upon receiving the equipment, check the integrity of the toilet body to ensure there are no cracks, deformations, or other damages; verify the配件清单 (accessory list) (such as door locks, flush valves, sewage pipes, sealing tapes, etc.), and immediately contact the supplier for replacement if any items are missing or damaged.
Foundation Preparation
- Clear ground debris according to the toilet type (single or connected units) and lay a gravel or concrete foundation layer.
- Ensure the foundation's load-bearing capacity meets the standard: The load-bearing capacity for a single-person toilet must be ≥200kg/㎡ to prevent box tilting or damage due to ground settlement.
II. On-site Installation Steps
Toilet Body Positioning
- Use a forklift or crane to smoothly hoist the toilet body to the designated location, maintaining a level position during hoisting to avoid tilting and potential safety hazards.
- When multiple people are involved in the operation, unified command is required to ensure the hoisting path is obstacle-free and prevent collision damage.
Drainage Connection
- Connect the sewage pipe to the construction site's drainage system or a temporary collection pit, wrapping the joint with sealing tape or sealing it with cement to prevent sewage leakage.
- It is recommended to install an anti-backflow valve to prevent the drainage system from backflowing and contaminating the interior of the toilet.
Flush System Debugging
- Connect to a water source (either tap water or a dedicated water tank), turn on the flush valve to test if the function is normal.
- Check if the drainage pipe is unobstructed; if water accumulates after flushing, investigate and repair issues such as pipe bending or blockage in a timely manner.
Internal and External Inspection
- Internal Inspection: Confirm that facilities such as washbasins, hooks, and toilet paper holders are securely installed without looseness; test if the door lock opens and closes smoothly.
- External Inspection: Check the toilet body's sealing performance, focusing on observing whether there are water or air leaks at the joints to ensure no odors escape during use.
After completing the above steps, the temporary mobile plastic toilet can be put into use. During the installation process, strictly follow operational procedures and conduct regular maintenance (such as cleaning sewage pipes and checking seals) to extend the equipment's service life and ensure hygiene conditions.