Regulations on Prefabricated Beams in Buildings

Admin September 18, 2026

The core regulations for prefabricated beams in buildings include the 'Technical Standard for Prestressed Prefabricated Concrete Frame Structures' and the specifications for lintel settings at openings, with specific requirements as follows:

I. Technical Standard for Prestressed Prefabricated Concrete Frame Structures

This standard has been approved as an industry standard by the Ministry of Housing and Urban-Rural Development and will be implemented from April 1, 2025. It is applicable to prestressed prefabricated concrete frame structures in areas with a seismic fortification intensity of 9 degrees or below. Its core content covers the classification, design conditions, and design combinations for the ultimate limit state of load-bearing capacity of prefabricated beams:

  1. Classification and Applicable Scenarios Prefabricated beams are classified into Class I, Class II, and Class III. Class I and Class II beams are suitable for areas with a seismic intensity of 8 degrees or below, while Class III beams are suitable for areas with a seismic intensity of 9 degrees or below. The classification is based on seismic performance requirements, with Class III beams needing to meet deformation and load-bearing capacity demands in higher-intensity areas.
  2. Design Conditions It is specified that prefabricated beams must consider design requirements under transient conditions (such as loads during the construction phase), persistent conditions (loads during normal use), seismic conditions (seismic action combinations), and accidental conditions (extreme events such as explosions or impacts) to ensure the safety of the structure throughout its entire lifecycle.
  3. Design Combinations for the Ultimate Limit State of Load-Bearing Capacity The calculation methods for basic combinations (persistent design conditions), accidental combinations (accidental design conditions), and seismic combinations (seismic design conditions) are specified, providing quantitative bases for the design of the strength, stiffness, and stability of prefabricated beams.

II. Specifications for Prefabricated Lintels at Openings

According to building regulations, when the width of a wall opening exceeds 300 mm, a lintel must be installed to support the load of the upper masonry and transfer it to the walls on both sides of the opening. This requirement applies to the structural design of openings such as doors and windows in building construction, with core requirements including:

  1. Installation Conditions When the width of an opening exceeds 300 mm, regardless of the wall material (such as bricks or blocks) or the number of stories, a lintel must be installed to prevent wall cracking or structural instability due to local stress concentration.
  2. Functional Requirements The lintel must bear the self-weight of the upper masonry and live loads and effectively transfer these loads to the walls on both sides of the opening to ensure the integrity of the structure around the opening. During design, considerations must be given to the span, cross-sectional dimensions, and reinforcement of the lintel to meet load-bearing capacity and deformation requirements.

III. Explanation of Other Relevant Standards

The 'Technical Standard for Segmental Prefabricated Concrete Bridges' (CJJ/T 111-2023) primarily targets bridge engineering and does not directly involve prefabricated beams in building construction. Case study information (such as projects by Shandong Huida Ruihe Building Materials Technology Co., Ltd. and China Construction Eighth Engineering Division) only illustrates the application practices of prefabricated beams and does not reflect regulatory content. Formal standard documents should be used as the basis.