Admin September 18, 2026

The common thicknesses of prefabricated panels in prefabricated panel houses are 120mm and 150mm, with 100mm being less frequently used. Other thicknesses can also be customized according to requirements. Here are the specific details:

Common Thickness Specifications
As a key component in house structures, the thickness design of prefabricated panels must balance load-bearing capacity, material economy, and construction convenience. Currently, the mainstream thicknesses of prefabricated panels on the market are 120mm and 150mm. The 120mm-thick prefabricated panels are suitable for buildings with lower load requirements, such as residential houses and office buildings, for example, as floor slabs or partition walls in ordinary residential houses. The 150mm-thick prefabricated panels are mostly used in scenarios with higher load-bearing capacity requirements, such as floor slabs in commercial buildings and industrial plants, or areas requiring enhanced sound insulation and thermal insulation. These two thicknesses, through standardized production, can meet the needs of most conventional buildings and achieve a balance between material costs and transportation and installation efficiency.

Unconventional Thickness and Customization Requirements
In addition to the common specifications, 100mm-thick prefabricated panels are also used in specific scenarios, but with lower frequency. These thin panels are typically used in parts with strict space height requirements and low loads, such as temporary buildings, light partitions, or decorative components. If architectural designs have special requirements for the thickness of prefabricated panels (such as ultra-thick panels for special load scenarios or ultra-thin panels for specific decorative needs), manufacturing enterprises can customize non-standard thickness prefabricated panels by adjusting the reinforcement configuration, concrete strength grade, and production process. However, customized products need to undergo structural calculations to verify their safety and may involve higher costs and longer production cycles.

Core Bases for Thickness Selection
The determination of the thickness of prefabricated panels requires comprehensive consideration of multiple factors:

  • Load Requirements: The intended use of the building (such as residential, commercial, or industrial) determines the standard value of the floor live load, and the thickness must meet the load-bearing capacity calculation.
  • Span and Reinforcement: When the panel span is large, it is necessary to control deflection by increasing the thickness or reinforcement ratio.
  • Functional Requirements: Performance requirements such as sound insulation, fire resistance, and thermal insulation may affect the thickness selection.
  • Economy: On the premise of ensuring safety, standardized thicknesses are preferred to reduce costs.

In actual engineering projects, design units will determine the thickness of prefabricated panels according to standards such as the "Code for Design of Concrete Structures" and in combination with specific working conditions, and clearly indicate them on construction drawings. Construction units must strictly follow the drawings during construction to ensure structural safety.