Back to blog
Article

Foundation Treatment for Prefabricated Houses

Admin September 18, 2026

The foundation treatment of prefabricated houses needs to be tailored according to the type of house. For old prefabricated panel houses in urban areas, inspection is the main focus, while for self-built prefabricated houses in rural areas, strict control over construction details and proper moisture-proof treatment are required.

Old Prefabricated Panel Houses in Urban Areas

It is essential to focus on checking for obvious settlement marks on the ground around the house, whether there are height differences between indoor and outdoor floors, and observing whether there are diagonal cracks at the bottom of the walls caused by uneven foundation settlement. These signs can help determine whether there are problems with the foundation. If problems are found, professional personnel should be contacted promptly for evaluation and treatment to prevent the problems from worsening and affecting the safety of the house.

Self-built Prefabricated Houses in Rural Areas

  • Soil Quality Assessment of Homestead Land: The soil quality of rural homestead land is complex and diverse, with significant differences in bearing capacity. It should not be judged solely based on experience. If possible, a professional soil survey agency should be selected for the survey. If you want to save costs, you can use a Luoyang shovel to dig several points on the homestead land to check the soil quality. For soft soil, backfilled soil, or soil with poor bearing capacity such as that from former ponds or ditches, soil replacement or the selection of a raft foundation is required.
  • Depth and Width of the Foundation Pit: Taking a strip foundation as an example, the depth of the foundation pit should be dug to the hard soil layer. If it is difficult to determine or the foundation requires soil replacement, it should be dug to a depth of at least 1.2 - 1.5 meters. The width of the foundation pit should be at least 0.8 meters. If the foundation is built on floating soil or the width is insufficient, the bearing capacity of the foundation will be insufficient in the later stage, leading to cracks or even tilting of the walls.
  • Setting a Bedding Layer: The bedding layer plays a crucial role. Generally, plain concrete of C10 or C15 is used, with a thickness of 10 centimeters. It can evenly transfer the upper load to the foundation, provide a flat working surface for steel bar binding, and isolate soil moisture to prevent steel bar corrosion. Not setting a bedding layer will affect the durability of the foundation.
  • Steel Bar Binding: The number, diameter, and stirrup spacing of the main steel bars in the ground beam must be calculated and should not be increased or decreased arbitrarily. The lap length of the steel bars should be sufficient, and spot welding should not be used instead of binding. National standard steel bars must be used, and non-standard steel bars are strictly prohibited.

Moisture-proof Treatment for the Foundation of Self-built Houses in Rural Areas

  • Laying a Moisture-proof Film: Use high-density polyethylene film to block underground moisture. After the foundation is backfilled and compacted, first lay fine sand and gravel, compact and level it, then lay the moisture-proof film, and finally pour a concrete bedding layer or floor. During construction, attention should be paid to the quality of the film, the selection of backfill soil, and the treatment of overlaps and joints.
  • Creating a Prefabricated Panel Suspended Floor: Leave a cavity of 30 - 50 centimeters between the foundation and the first-floor ground to allow underground moisture to dissipate in the cavity. After the ground beam is poured, control the height of the backfill soil to be 30 - 50 centimeters from the ground and compact it.