Water Leakage in the Exterior Walls of Prefabricated Houses
Water leakage in the exterior walls of prefabricated houses requires targeted leak-repair measures based on specific causes. Common causes include joint seams, wall cracks, and aging of the waterproof layer. Here are specific analyses and handling suggestions:

Joint Seam Treatment is Key
The exterior walls of prefabricated houses are composed of multiple prefabricated components joined together, and joint seams are a high-risk area for water leakage. If the joint seams are not sealed tightly, rainwater can easily penetrate indoors through the gaps. When treating them, first clear away debris, dust, and aged sealant from the seams to ensure the base is dry and clean. Then, use a weather-resistant sealant (such as silicone sealant) to refill the seams, ensuring the sealant is full, bubble-free, and has a smooth surface. Finally, a waterproof membrane can be added on the outside of the sealant or a waterproof coating can be applied to form double protection and enhance the waterproof effect.
Wall Cracks Need Repair
Wall cracks are another important cause of exterior wall water leakage, which may be caused by foundation settlement, temperature changes, or construction quality issues. For tiny cracks less than 0.2mm wide, pressure grouting can be used to inject waterproof grout such as epoxy resin into the cracks to fill them and enhance the structural strength of the wall. For wider cracks, first chisel out a 'V'-shaped groove along both sides of the crack, clean it thoroughly, and then fill it in layers with cement mortar or polymer mortar, with each layer not exceeding 15mm in thickness. Wait for the previous layer of mortar to set before filling the next layer, and finally apply a waterproof coating on the surface.
Aging of the Waterproof Layer Requires Replacement
If the exterior wall waterproof layer ages, cracks, or peels off due to long-term exposure to the natural environment, its waterproof function will be lost. In this case, the original aged waterproof layer must be completely removed, and the base must be cleaned to a solid and flat state. When reapplying the waterproof coating, ensure even application without missed spots and that the application thickness meets the design requirements (generally not less than 1.5mm). For important areas or areas with a high risk of water leakage, additional waterproof membranes can be applied, with a lap width of not less than 100mm, and the lap edges must be sealed with sealant.
Exterior Wall Interfaces and Joints Need Inspection
The connections between window and door frames, air conditioner brackets, and the wall on the exterior walls, as well as the junctions between different materials (such as the junction between concrete and brick masonry), are also prone to water leakage if not sealed tightly. When treating them, first clear away debris and aged sealing materials from the interfaces, and then reseal them with weather-resistant sealant to ensure the sealant adheres firmly to the base without voids. For junctions between different materials, alkali-resistant fiberglass mesh can be added at the junction to enhance crack resistance, and then a waterproof coating can be applied.