The inspection of mobile toilets in Nantong should be carried out comprehensively from four aspects: inspection institutions and plans, inspection standards, testing methods, and inspection report content.

Inspection Institutions and Plans: The inspection of mobile toilets in Nantong is usually undertaken by third-party professional inspection institutions, which are required to provide a complete inspection plan. The plan covers architectural and structural verification, structural damage condition inspection, structural safety calculation and analysis, as well as steel material performance testing (such as non-destructive testing of steel structure welds and mechanical property testing of steel materials). These inspections aim to comprehensively evaluate the physical performance and material quality of the toilets to ensure they meet design requirements.
Inspection Standards: The inspection must strictly adhere to multiple standards. The equipment must be brand new and unused, meeting the quality, specifications, and performance requirements specified in the bidding technical documents. Under correct installation, use, and maintenance conditions, the performance should meet expectations throughout its service life. The quantity of equipment and material usage should be consistent with the technical specifications in the bidding documents. The overall wind resistance should be no less than Level 10, the earthquake resistance should be no less than Level 8, and the service life should be no less than 10 years. These standards ensure the durability and safety of the toilets.
Testing Methods: The inspection process includes supervision testing, on-site testing, and operational testing. Supervision testing can be conducted during the manufacturing process or before shipment, with the purchasing party sending personnel to supervise and conduct pre-acceptance. On-site testing requires joint unpacking inspection with the purchasing party and acceptance according to the scope of supply list. Operational testing is carried out after construction installation and commissioning, requiring trouble-free trial operation and confirmation by the using unit and department. In addition, special tests such as appearance and decorative quality inspection, wind resistance testing, sealing and waterproof testing, and enclosure tightness testing are also required to ensure that all performance aspects of the toilets meet standards.
Inspection Report Content: The inspection report should detail the inspection results in terms of structural safety, sanitary conditions, electrical systems, operational status, and environmental performance. Structural safety should assess the strength of frame materials, the stability of connecting components, and the overall structural stability. Sanitary conditions should inspect the surface of the toilet bowls, cleaning tools, and the sewage system. The electrical system should inspect the safety of power lines, the installation positions of sockets, and the working status of lighting equipment. Operational status should record abnormal noises, vibrations, etc. Environmental performance should evaluate the effectiveness of the sewage treatment system and equipment energy consumption.