Sinking Height of Mobile Toilets
There is currently no unified standard for the sinking height of mobile toilets, but reference can be made to the general data of sunken bathrooms, typically ranging from 20cm to 40cm, with specifics depending on actual conditions.

The design principle of a sunken bathroom (also known as a sunken-tank bathroom) involves lowering the height of the bathroom's ground structural layer to create a sunken space for arranging drainage pipes, preventing pipe exposure from affecting ceiling height or aesthetics. The sinking height is usually determined by factors such as pipe layout, drainage slope, and the thickness of the backfill material. The conventional sinking height range is 30cm to 40cm. For example, in ordinary residences, if a DN110 drainage pipe is used, the combined calculation of pipe diameter, drainage slope (usually 2%-3%), and the thickness of the backfill layer (such as expanded clay concrete or lightweight aggregate) often results in a sinking height within this range.
In some scenarios, the sinking height may be lower. If the pipe layout is compact or a special drainage system (such as same-floor drainage) is used, the local sinking height may be reduced to 20cm to 30cm (i.e., 200mm to 300mm). For instance, mobile toilets in some hotels or public buildings, due to space constraints, may reduce the sinking depth by optimizing pipe routing or using thin backfill materials, but must ensure that the drainage slope meets specifications (generally not less than 1%) to avoid water accumulation or blockage.
The particularities of mobile toilets require additional consideration. Unlike traditional fixed bathrooms, mobile toilets may involve modular design, movable structures, or lightweight materials, and their sinking height must balance stability and portability. For example, mobile toilets used temporarily outdoors may replace sinking design by raising the foundation or adjusting the ground slope to reduce construction complexity; while permanently fixed mobile toilets may refer to the standards of sunken bathrooms but require personalized adjustments based on foundation conditions (such as deepening the sinking on soft soil foundations to enhance stability) or usage needs (such as controlling step height for barrier-free design).
The final height requires comprehensive evaluation. In actual engineering, the sinking height of mobile toilets must be calculated and determined by the design unit based on factors such as pipe type (e.g., diameter of sewage and vent pipes), drainage volume, performance of backfill materials (e.g., bulk density, compressive strength), and usage scenarios (e.g., foot traffic, cleaning frequency), and must comply with specifications such as the "Building Water Supply and Drainage Design Standard" (GB 50015) to ensure smooth drainage, structural safety, and ease of maintenance.