What Items Are Inspected for Mobile Toilets
The inspection items for mobile toilets mainly include structural safety, internal equipment, water supply and drainage systems, electrical systems, environmental protection systems, sanitation condition inspections, and core inspection items by third-party inspection agencies, among others. Details are as follows:

Structural Safety Inspection: Check whether the overall structure of the public toilet is stable, and whether there are issues such as tilting, cracks, or deformation. Visual inspection can be conducted, and tools such as spirit levels and rangefinders can be used to check structural stability and perpendicularity. Pressure testing equipment can be used to detect the load-bearing capacity of the floor. Additionally, architectural and structural verification can be carried out, including sampling and verifying the building layout based on original design documents; comprehensively inspecting structural damage, focusing on the aging and deformation of main load-bearing components; conducting structural safety calculations and analyses based on codes and on-site investigations; and performing non-destructive testing on welds in steel structures according to the owner's requirements to test the mechanical properties of the steel.
Internal Equipment Inspection: Check the integrity and working condition of equipment such as toilets, urinals, and sinks. Visual inspection can be used to check for damage or cracks on the equipment's exterior; practical operation can be used to check whether the drainage functions of each piece of equipment are unobstructed.
Water Supply and Drainage System Inspection: Check the water supply pressure of the water supply system and the drainage capacity of the drainage system to ensure there are no leaks or blockages. A water pressure gauge can be used to test whether the pressure in the water supply pipes is within the normal range; practical water discharge tests can be used to check the smoothness of the drainage pipes.
Electrical System Inspection: Check the safety and functionality of the electrical system, including lighting, ventilation, and heating devices. A voltmeter and ammeter can be used to test the working voltage and current of electrical equipment to ensure they are within the safe range; practical operation can be used to check the working condition of each piece of electrical equipment, such as whether the lighting is normal and whether the ventilation is effective.
Environmental Protection System Inspection: Check the working condition of water-saving devices and deodorization devices to ensure environmental protection effects. The water-saving effect of water-saving devices can be tested through actual water consumption; an odor detector can be used to test the working effect of deodorization devices and check for any odors.
Sanitation Condition Inspection: Check the overall sanitation condition of the mobile public toilet, including whether the floor, walls, and equipment surfaces are clean and hygienic. Visual inspection can be used to check for obvious stains or garbage inside the public toilet; bacterial culture dishes can be used for sampling, followed by bacterial culture and analysis to detect the sanitation condition.
Core Inspection Items by Third-Party Inspection Agencies: These include structural stability tests, material corrosion resistance tests, formaldehyde and VOC emission tests, surface colony count and Escherichia coli group tests, among others.