The mobile toilet design specification covers multiple aspects such as spatial layout, materials, hygiene, and ventilation, as detailed below:

Spatial Layout and Dimensions: The internal spatial layout should be reasonable and conform to ergonomic principles. Common dimensions include a length of 1.1 - 1.5 meters, a width of 0.8 - 1.2 meters, and a height of 2.3 - 2.7 meters, ensuring comfortable use of toilet stalls and urinals by individuals of different body types. The width of toilet stalls should not be less than 0.8 meters for easy access; the position of urinals should be convenient for use and consider privacy protection; facilities such as sinks and mirrors should adhere to ergonomic design. Additionally, the needs and convenience of barrier-free and children's facilities should be considered.
Material Selection and Structural Stability: Durable, weather-resistant, and environmentally friendly materials should be selected, such as stainless steel or fiberglass-reinforced plastic for the outer shell and interior walls and floors, to extend service life and ensure safety. The structural design must be stable and robust, meeting stability requirements during transportation, installation, and daily use, with an internal structure that facilitates cleaning and maintenance operations.
Hygiene Conditions and Ventilation: Hygiene conditions should meet relevant regulations, including cleanliness and antibacterial properties of floors, walls, and ceilings. A good ventilation system should be in place, utilizing natural or mechanical ventilation methods to ensure smooth air circulation within the restroom and effectively reduce odors.
Waterproofing and Drainage: Reliable waterproofing and drainage functions are essential to prevent sewage leakage from affecting the environment and users. Waterproof materials such as waterproof coatings and membranes should be selected during design, while ensuring the drainage system remains unobstructed to prevent blockages and overflows.
Sound Insulation and Thermal Insulation: The restroom should have good sound insulation and thermal insulation properties to ensure user comfort and privacy. Sound insulation and thermal insulation materials such as soundproofing mats and thermal insulation boards can be considered during design.
Equipment Configuration and Humanized Design: Well-equipped facilities such as toilet stalls, sinks, mirrors, and paper towel holders should be provided to meet users' basic needs. Humanized design is also important, such as incorporating barrier-free facilities and providing sufficient lighting.
Environmental Protection and Energy Efficiency: The design should adhere to principles of environmental protection and energy efficiency, prioritizing the selection of low-energy equipment and materials such as energy-efficient lighting fixtures and low-flow faucets. Natural light and ventilation should be utilized reasonably to reduce the use of artificial lighting and mechanical ventilation, thereby lowering energy consumption. Environmentally friendly materials and processes, such as biodegradable waste disposal devices, should also be considered.
Mobility Convenience: The overall structure should be lightweight, utilizing lightweight and durable materials as much as possible; the structure should be sturdy; the height and width of the toilet should be carefully considered during design; and the mobility device should be fully considered for completeness and rationality.