Lianjiang Mobile Toilet Installation
The installation of the foot-pedal bag for mobile toilets in Lianjiang can be carried out according to the following steps, ensuring that operations are standardized to guarantee the normal functioning of the equipment:

I. Installation of the Foot-Pedal Bag Main Body
Locate Installation Holes
Inspect the side or bottom edge of the public toilet barrel to find the reserved installation holes. The hole positions must match the dimensions of the iron rod and connecting rod components of the foot-pedal bag, ensuring that the iron rod can be inserted vertically and move freely without obstruction. If the holes are covered with dirt, clean them first to avoid installation deviations caused by impurities.Insert the Iron Rod and Connect the Connecting Rod
Align the iron rod with the holes and insert it vertically as the core component of the transmission mechanism. Then, connect the connecting rod to the foot-pedal component, aligning with the connection points (such as pin holes or slots) to ensure that stepping on the pedal can open and close the lid in tandem. If the connecting rod has rollers, confirm that the rollers can fit into the lid track to avoid不畅 (不畅 here means '不畅' in Chinese, which can be translated as 'stuttering' or 'poor movement') in lid opening and closing due to jamming.Secure Components
Use the pins or screws provided in the accessories to secure the connection points. Tighten the screws for the iron rod's fixation to the barrel until there is no looseness; the connection between the connecting rod and the foot-pedal can be locked with a pin to prevent disconnection. It is recommended to repeatedly check each connection point to avoid transmission failure or equipment damage due to looseness.
II. Installation of Foot-Pedal Valve Devices (If Involving a Water Supply System)
Clean the Water Supply Pipe
Before installation, flush the pipe with water to remove iron filings, debris, etc., to prevent damage to the sealing gasket. This step is crucial for preventing leaks and ensuring the internal cleanliness of the pipe.Reserve Installation Dimensions
Ensure that the distance between the inlet and outlet pipes is 75±3mm to avoid misalignment of the valve body or poor sealing due to dimensional deviations. If the dimensions do not match, adjust the pipe position or contact the manufacturer to replace with compatible components.Main Body Installation and Sealing
Remove the movable joint of the foot-pedal valve, wrap an appropriate amount of Teflon tape (filler) around the threaded part of the pipe joint, screw it in 6-7 threads, and then adjust the direction of the water outlet. Sequentially place a nut and a beveled rubber ring (bevel facing upwards) on the upper end of the downpipe, insert the outlet pipe into the valve body's outlet, and tighten the nut to secure it. Place a flat rubber gasket on the threaded part of the valve body's inlet, tighten the nut, and then use a wrench to reinforce the connection of the inlet and outlet pipes to ensure no leakage.
III. Testing and Acceptance
Function Testing
Step on the foot-pedal multiple times to check if the lid opens and closes smoothly and if the connecting rod's rollers slide along the track. If the lid opens and closes with stuttering or leaks, readjust the connection points or sealing components.Leakage Inspection
After turning on the water supply, observe whether there are any leaks at the connections of the valve body (such as the inlet and outlet, nut connections). If leaks are found, immediately turn off the water supply and retighten the nuts or replace the sealing gaskets.
If you encounter mismatched hole positions, damaged components, or operational difficulties during installation, it is recommended to contact the manufacturer or professional maintenance personnel to avoid equipment damage or safety hazards caused by self-installation. Additionally, mobile toilet rental and sales services are available in the Lianjiang area. Contact 4000365770 for more installation support.